MAKE | MODEL | CHASSIS | SYMPTOM | CURE | |
GE | 1CVD5023X | N/A | ERRATIC REEL MOTOR--MAY ALSO HAVE A HIGH PITCHED WHINE | CHECK C2523 FOR OPEN | |
GE | 1CVT645 | N/A | DISPLAY MISSING--NO FUNCTIONS | CHECK C7507 FOR LEAKAGE | |
GE | 1VCR3000X | N/A | NO SPEED SELECT | IC601 | |
GE | 1VCR4012X | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 1VCR4012X | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 1VCR4012X | N/A | ALL MODES OPERATIONAL NO FIP DISPLAY | CHECK FILAMENT VOLT.MISSING CHECKPINS7&8 OF T1001 | |
GE | 1VCR4012X | N/A | WHEN PLAY IS PRESSED,VCR RUNS FOR 2-5 SECONDS THEN SHUTS OFF-NEVER SWITCHES FROM TUNER TO VCR-LOADING MOTOR RUNS ON | CHECK/REPLACE MODE SELECT SWITCH | |
GE | 1VCR4012X | N/A | WEAK AUDIO (PLAYBACK ONLY) | CHECK C4014 | |
GE | 1VCR4012X | N/A | NO EE OR VV VIDEO AUDIO OK | CHECK/REPLACE IC3101 | |
GE | 1VCR4012X | N/A | CAPSTAN MOTOR RUNS ABOUT 8SEC. THEN SHUTS DOWN | CHECK R6070 | |
GE | 1VCR4012X | N/A | VIDEO FROM RF VIDEO OUTLOOKS SCRAMBLED | CHECK VIDEO SIGNAL ON BOTH SIDES OF C3014 | |
GE | 1VCR4012X | N/A | SQUEL FROM THE POWER SUPP WHEN PLUGGED IN | CHECK D1023 | |
GE | 1VCR4012X | N/A | WILL NOT RECORD WHEN TIMER IS SET | CHECK/CLEAN ERASE PROTECT SWITCH CONTACTS | |
GE | 1VCR4012X | N/A | NO POWER UP--FIP OK,POWER SUPPLY OK | CK PIN #16 OF IC6001 (4-5V)--IF LOW,CK C6009 | |
GE | 1VCR4012X | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 1VCR4012X | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 1VCR4012X | N/A | EXCESSIVE WOW AND FLUTTER | CHECK/REPLACE C2004 (BREAKING DOWN UNDER LOAD OR HIGH ESR) | |
GE | 1VCR4012X | N/A | POWERS UP-LOADS TAPE-NO PLAY,REC,EJECT,FF,REW | REPLACE IC7501 | |
GE | 1VCR4012X | N/A | CAPSTAN MOTOR OSCILLATES BACK & FORTH | REPLACE IC2002 | |
GE | 1VCR4012X | N/A | STARTS PLAYING THEN STOPS;COUNTER DOESN'T WORK | CHECK IC1551 | |
GE | 1VCR4012X | N/A | NO COLOR ON PLAYBACK OF PRE-RECORDED TAPES | CHECK/REPLACE IC8101 (MN6163) | |
GE | 1VCR4012X | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FORFEW SECS | CHECK/ REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR4012X | N/A | NO COLOR IN PLAY BACK ONLY | REPLACE IC3502 ON THE HEAD AMP CBA | |
GE | 1VCR4012X | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FOR A FEW S | CHECK / REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR4012X | N/A | NO AUDIO | CHECK/REPLACE Q7010 & Q7002 | |
GE | 1VCR4012X | N/A | FAILURE TO PASS LEAKAGE CURRENT HOT CHECK | CHECK OR REPLACE C1005 | |
GE | 1VCR4012X | N/A | DISTORTION OF CASSETTE TRAY SIDE PLATE | CHECK R6070 RC00043,PLOO144,IC6001 | |
GE | 1VCR4012X | N/A | POWER SUPPLY TICKS WHEN PLUGGED IN AND ALL SECONDARY VOLTAGES ARE LOW. | CHECK R1002 (680k) FOR OPEN | |
GE | 1VCR4012X | N/A | PUSH PLAY AND TAPE GOES TO REWIND | CHECK/REPLACE END SENSORS | |
GE | 1VCR4012X | N/A | SNOWY PIX IN PLAYBACK ONLY AUDIO OK | CHECK Q3001 | |
GE | 1VCR4012X | N/A | TOP & BOTTOM 2' OF PIX. OK CENTER SNOWY | CHECK OR REPLACE IC8102 | |
GE | 1VCR4012X | N/A | NO TRACKING CONTROL MAY LOCK IN BRIEFLY | CHECK/REPLACE IC2002 | |
GE | 1VCR4012X | N/A | UNIT TICKS WHEN PLUGGED IN NO FIP | R1039 | |
GE | 1VCR4012X | N/A | INTERMITTENTLY STOPS PLAYING W/KNOWN GOOD TAPE | CHECK Q1552 (SUPPLY PHOTO XSTR) | |
GE | 1VCR4012X | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 1VCR4012X | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 1VCR4012X | N/A | WON'T POWER UP--DRUM RUNS CONTINUOUSLY | REPLACE IC6001 (MN15846VRG) | |
GE | 1VCR4012X | N/A | REDUCED CLOCK & DAY BRILLIANCE | CHECK R1215 | |
GE | 1VCR4012X | N/A | NO AUTO STOP AT END OF TAPE IN PLAY FAST FOR REW | CHECK/REPLACE Q6008 | |
GE | 1VCR5002X | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 1VCR5002X | N/A | PLAYBACK/RECORD ONLY IN SP LP&SLP CAPSTAN QUIVER | READJUSTMENT OF THE FG HEAD | |
GE | 1VCR5002X | N/A | TAPE LEFT HANGING FROM CASSETTE;IDLER OK | CHECK MODE SELECT SWITCH | |
GE | 1VCR5002X | N/A | PLAYS HALF OF TAPE CAPSTAN DRIVE IC HOT | REPLACE CAPSTAN BEARING ASSEMBLY | |
GE | 1VCR5002X | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 1VCR5002X | N/A | NO FIPS OPERATION CYLD. MOTOR RUNS ALL THE TIME | IF POWER SUPPLY VOLTAGES ARE LOW CHECK D1006 | |
GE | 1VCR5002X | N/A | NO POWER NO DISPLAY FUSE OK | CHECK FOR DEFECTIVE Q1 INTHE POWER SUPPLY | |
GE | 1VCR5002X | N/A | DEAD SET BUT NO FUSES BLOWN | CHECK/REPLACE Q1001,D1007 AND D1005 | |
GE | 1VCR5002X | N/A | WILL NOT TIME RECORD | CLEAN THE POINTS ON AND/OR REPLACE THE SAFETY SWITCH | |
GE | 1VCR5002X | N/A | STOPS OR SHUTDOWN AFTER 1 TO 2 HOURS OF PLAYING | REPLACE THE CAPSTAN HOUSING | |
GE | 1VCR5002X | N/A | EXCESSIVE BRIGHTNESS IN PLAYBACK;E-E PIX OK | ADJUST WHITE CLIP R3101 (REFER TO MANUAL) | |
GE | 1VCR5002X | N/A | ERRATIC FUNCTIONS--PLAY>STOP RESULTS PLAY>REWIND | CHECK FOR DIRTY MODE SELECT SWITCH OR SWITCH TIMING. | |
GE | 1VCR5002X | N/A | WILL NOT RECORD OR PLAYBACK AUDIO | CHECK/REPLACE IC4003 | |
GE | 1VCR5002X | N/A | ERRATIC CAPSTAN MOTOR OPERATION | CHECK/REPLACE IC2601 | |
GE | 1VCR5002X | N/A | INTERMITTENT NORMAL PIX TO SNOW AFTER SEVERAL HO | REPLACE IC2001 | |
GE | 1VCR5002X | N/A | CAPSTAN STOPS AFTER 1/2 HOUR--IC VERY HOT!!! | CHECK CAPSTAN BEARINGS OR FLYWHEEL FOR SCARS | |
GE | 1VCR5002X | N/A | TAPE LOADS IS IMMEDIATELY EJECTED | CHECK D6013 FOR LEAKAGE | |
GE | 1VCR5002X | N/A | HORIZ. ROLLING LINES IN PIX WITH VCR OFF | CHECK OR REPLACE THE VHF BLOCK | |
GE | 1VCR5002X | N/A | WHEN PLAY BUTTON IS PRESSED ALL DISP. SEG. GOOUT | CHECK Q1001 | |
GE | 1VCR5002X | N/A | WILL NOT GO INTO RECORD MAY CONT UNLOAD AND LOAD | REPLACE THE MODE SELECT SWITCH | |
GE | 1VCR5002X | N/A | REACTION TIME TO ALL FUNCTIONS IS SLOW | CHECK MODE SELECT SWITCH | |
GE | 1VCR5002X | N/A | LEAVES THE TAPE HANGING FROM EJECTED CASSETTE | CHECK THE FELT ON THE TENSION BAND UNIT | |
GE | 1VCR5002X | N/A | FIP INDCATES PROPER MODE CAPSTAN FAILS TO RUN | CHECK Q2005 | |
GE | 1VCR5002X | N/A | POWER BUTTON INOPERATIVE-WILL NOT TURN OFF | CHECK D6049 (MAY CHECK OK IN CIRCUIT) | |
GE | 1VCR5002X | N/A | UNIT POWERS UP NO PLAY FF REWIND | CHECK/REPLACE C6032 | |
GE | 1VCR5002X | N/A | SLUGGISH AUDIO;NOISE BARS IN PIX;WILL NOT ADJUST | CHECK THE CAPSTAN IC OR FLYWHEEL BEARINGS | |
GE | 1VCR5002X | N/A | UNIT WILL NOT ALWAYS LOAD | CHECK 'C' RING WHICH HOLDS THE CAM GEAR IN PLACE | |
GE | 1VCR5002X | N/A | GARBLED AUDIO IN LP AND SLP | CHECK IC4705,PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 1VCR5002X | N/A | DD CYLND.SHUTS OFF AFTER LOADING IS FINAL | REPLACE D6054 | |
GE | 1VCR5002X | N/A | TAPE LOAD/UNLOAD SLUGGISH-LEAVE TAPE HANGING OUT | CHECK Q1013 AND D1022 FOR SHORTS OR OPENS | |
GE | 1VCR5002X | N/A | WHILE PLAYING GOES INTO REVIEW | CHECK/REPLACE IC6001 | |
GE | 1VCR5002X | N/A | IMMEDIATELY SHUTS OFF WITH POWER UP OF UNIT | CHECK OR REPLACE IC7001,21011,21013 | |
GE | 1VCR5002X | N/A | PLAY ENGAGED,LOADS,COUNTER FAILS TO COUNT,STOPS | Q6020,D6022 | |
GE | 1VCR5002X | N/A | NO COLOR IN PLAYBACK LIGHT HORINZ. BAR BEHIND VI | CHECK C5 IN THE POWER SUPPLY | |
GE | 1VCR5002X | N/A | VERY BRIGHT FIP | CHECK D1015 IN POWER SUPPLY | |
GE | 1VCR5002X | N/A | INTERMITTENT COLOR SMEAR AND WHITE LINES IN PB | CHECK Q1009,Q1010 ESPECIALLY IF IC1001 IS SHORTED | |
GE | 1VCR5002X | N/A | COMPLETELY DEAD | CHECK R1001,R1034,R1006 FOR OPEN CONDITIONS | |
GE | 1VCR5002X | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 1VCR5002X | N/A | LOADING MOTOR WILL NOT RUN ALL FUNCT INOPERABLE | CHECK Q6009 | |
GE | 1VCR5002X | N/A | INTERMITTENTLY SHUTS DOWN | CHECK FOR DEFECTIVE DD CYLINDER | |
GE | 1VCR5002X | N/A | NO FIP DISPLAY | CHECK R1030 | |
GE | 1VCR5002X | N/A | FF/CUE WILL NOT RELEASE UNTIL STOP IS PRESSED | REPLACE IC2601 | |
GE | 1VCR5002X | N/A | WILL NOT REWIND OR FAST FORWARD - NO CAPSTAN OPERATIONS | CHECK/REPLACE Q2005 | |
GE | 1VCR5002X | N/A | NO VIDEO-TUNER LEDS AND CHANNEL CHANGE OK | CHECK R1023 | |
GE | 1VCR5002X | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 1VCR5002X | N/A | PLAYS 3 TO 4 SECONDS THEN GOES TO STOP | CHECK D6021 D6022 D6023 AND D6024 FOR LEAKY SHORTCOND | |
GE | 1VCR5002X | N/A | ERRATIC FUNCTIONS | CHECK/CLEAN/REPLACE MODE SELECT SWITCH | |
GE | 1VCR5002X | N/A | LOADS TAPE AROUND HEAD WHEN EITHER FF/REW PUSHED | REPLACE MODE SELECT SWITCH | |
GE | 1VCR5011X | N/A | DROPOUTS IN AUDIO AND SOMETIMES VIDEO WHEN VIEWING A RECORDING - MAY TAKE MINUTES OR HOURS TO SHOW UP | CHECK/REPLACE INTERMITTENT ERASE PROTECT SWITCH | |
GE | 1VCR6004 | N/A | FAILURE TO PASS LEAKAGE CURRENT HOT CHECK | CHECK OR REPLACE C1005 | |
GE | 1VCR6004 | N/A | NO EE OR VV VIDEO AUDIO OK | CHECK/REPLACE IC3101 | |
GE | 1VCR6004 | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 1VCR6004 | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 1VCR6004 | N/A | NO COLOR IN PLAY BACK ONLY | REPLACE IC3502 ON THE HEAD AMP CBA | |
GE | 1VCR6004 | N/A | REDUCED CLOCK & DAY BRILLIANCE | CHECK R1215 | |
GE | 1VCR6004 | N/A | PUSH PLAY AND TAPE GOES TO REWIND | CHECK/REPLACE END SENSORS | |
GE | 1VCR6004 | N/A | WILL NOT RECORD WHEN TIMER IS SET | CHECK/CLEAN ERASE PROTECT SWITCH CONTACTS | |
GE | 1VCR6004 | N/A | SNOWY PIX IN PLAYBACK ONLY AUDIO OK | CHECK Q3001 | |
GE | 1VCR6004 | N/A | VIDEO FROM RF VIDEO OUTLOOKS SCRAMBLED | CHECK VIDEO SIGNAL ON BOTH SIDES OF C3014 | |
GE | 1VCR6004 | N/A | NO POWER UP--FIP OK,POWER SUPPLY OK | CK PIN #16 OF IC6001 (4-5V)--IF LOW,CK C6009 | |
GE | 1VCR6004 | N/A | POWER SUPPLY TICKS WHEN PLUGGED IN AND ALL SECONDARY VOLTAGES ARE LOW. | CHECK R1002 (680k) FOR OPEN | |
GE | 1VCR6004 | N/A | ALL MODES OPERATIONAL NO FIP DISPLAY | CHECK FILAMENT VOLT.MISSING CHECKPINS7&8 OF T1001 | |
GE | 1VCR6004 | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 1VCR6004 | N/A | EXCESSIVE WOW AND FLUTTER | CHECK/REPLACE C2004 (BREAKING DOWN UNDER LOAD OR HIGH ESR) | |
GE | 1VCR6004 | N/A | WON'T POWER UP--DRUM RUNS CONTINUOUSLY | REPLACE IC6001 (MN15846VRG) | |
GE | 1VCR6004 | N/A | WHEN PLAY IS PRESSED,VCR RUNS FOR 2-5 SECONDS THEN SHUTS OFF-NEVER SWITCHES FROM TUNER TO VCR-LOADING MOTOR RUNS ON | CHECK/REPLACE MODE SELECT SWITCH | |
GE | 1VCR6004 | N/A | WEAK AUDIO (PLAYBACK ONLY) | CHECK C4014 | |
GE | 1VCR6004 | N/A | STARTS PLAYING THEN STOPS;COUNTER DOESN'T WORK | CHECK IC1551 | |
GE | 1VCR6004 | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 1VCR6004 | N/A | UNIT TICKS WHEN PLUGGED IN NO FIP | R1039 | |
GE | 1VCR6004 | N/A | DISTORTION OF CASSETTE TRAY SIDE PLATE | CHECK R6070 RC00043,PLOO144,IC6001 | |
GE | 1VCR6004 | N/A | NO COLOR ON PLAYBACK OF PRE-RECORDED TAPES | CHECK/REPLACE IC8101 (MN6163) | |
GE | 1VCR6004 | N/A | TOP & BOTTOM 2' OF PIX. OK CENTER SNOWY | CHECK OR REPLACE IC8102 | |
GE | 1VCR6004 | N/A | NO TRACKING CONTROL MAY LOCK IN BRIEFLY | CHECK/REPLACE IC2002 | |
GE | 1VCR6004 | N/A | SQUEL FROM THE POWER SUPP WHEN PLUGGED IN | CHECK D1023 | |
GE | 1VCR6004 | N/A | POWERS UP-LOADS TAPE-NO PLAY,REC,EJECT,FF,REW | REPLACE IC7501 | |
GE | 1VCR6004 | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 1VCR6004 | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FOR A FEW S | CHECK / REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR6004 | N/A | INTERMITTENTLY STOPS PLAYING W/KNOWN GOOD TAPE | CHECK Q1552 (SUPPLY PHOTO XSTR) | |
GE | 1VCR6004 | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 1VCR6004 | N/A | CAPSTAN MOTOR RUNS ABOUT 8SEC. THEN SHUTS DOWN | CHECK R6070 | |
GE | 1VCR6004 | N/A | CAPSTAN MOTOR OSCILLATES BACK & FORTH | REPLACE IC2002 | |
GE | 1VCR6004 | N/A | NO AUDIO | CHECK/REPLACE Q7010 & Q7002 | |
GE | 1VCR6004 | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FORFEW SECS | CHECK/ REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR6004 | N/A | NO AUTO STOP AT END OF TAPE IN PLAY FAST FOR REW | CHECK/REPLACE Q6008 | |
GE | 1VCR6010X | N/A | PUSH PLAY AND TAPE GOES TO REWIND | CHECK/REPLACE END SENSORS | |
GE | 1VCR6010X | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 1VCR6010X | N/A | FAILURE TO PASS LEAKAGE CURRENT HOT CHECK | CHECK OR REPLACE C1005 | |
GE | 1VCR6010X | N/A | ALL MODES OPERATIONAL NO FIP DISPLAY | CHECK FILAMENT VOLT.MISSING CHECKPINS7&8 OF T1001 | |
GE | 1VCR6010X | N/A | WHEN PLAY IS PRESSED,VCR RUNS FOR 2-5 SECONDS THEN SHUTS OFF-NEVER SWITCHES FROM TUNER TO VCR-LOADING MOTOR RUNS ON | CHECK/REPLACE MODE SELECT SWITCH | |
GE | 1VCR6010X | N/A | NO COLOR IN PLAY BACK ONLY | REPLACE IC3502 ON THE HEAD AMP CBA | |
GE | 1VCR6010X | N/A | NO EE OR VV VIDEO AUDIO OK | CHECK/REPLACE IC3101 | |
GE | 1VCR6010X | N/A | NO COLOR ON PLAYBACK OF PRE-RECORDED TAPES | CHECK/REPLACE IC8101 (MN6163) | |
GE | 1VCR6010X | N/A | SQUEL FROM THE POWER SUPP WHEN PLUGGED IN | CHECK D1023 | |
GE | 1VCR6010X | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 1VCR6010X | N/A | INTERMITTENTLY STOPS PLAYING W/KNOWN GOOD TAPE | CHECK Q1552 (SUPPLY PHOTO XSTR) | |
GE | 1VCR6010X | N/A | CAPSTAN MOTOR RUNS ABOUT 8SEC. THEN SHUTS DOWN | CHECK R6070 | |
GE | 1VCR6010X | N/A | NO AUDIO | CHECK/REPLACE Q7010 & Q7002 | |
GE | 1VCR6010X | N/A | VIDEO FROM RF VIDEO OUTLOOKS SCRAMBLED | CHECK VIDEO SIGNAL ON BOTH SIDES OF C3014 | |
GE | 1VCR6010X | N/A | NO POWER UP--FIP OK,POWER SUPPLY OK | CK PIN #16 OF IC6001 (4-5V)--IF LOW,CK C6009 | |
GE | 1VCR6010X | N/A | DISTORTION OF CASSETTE TRAY SIDE PLATE | CHECK R6070 RC00043,PLOO144,IC6001 | |
GE | 1VCR6010X | N/A | POWER SUPPLY TICKS WHEN PLUGGED IN AND ALL SECONDARY VOLTAGES ARE LOW. | CHECK R1002 (680k) FOR OPEN | |
GE | 1VCR6010X | N/A | POWERS UP-LOADS TAPE-NO PLAY,REC,EJECT,FF,REW | REPLACE IC7501 | |
GE | 1VCR6010X | N/A | EXCESSIVE WOW AND FLUTTER | CHECK/REPLACE C2004 (BREAKING DOWN UNDER LOAD OR HIGH ESR) | |
GE | 1VCR6010X | N/A | NO TRACKING CONTROL MAY LOCK IN BRIEFLY | CHECK/REPLACE IC2002 | |
GE | 1VCR6010X | N/A | TOP & BOTTOM 2' OF PIX. OK CENTER SNOWY | CHECK OR REPLACE IC8102 | |
GE | 1VCR6010X | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 1VCR6010X | N/A | WON'T POWER UP--DRUM RUNS CONTINUOUSLY | REPLACE IC6001 (MN15846VRG) | |
GE | 1VCR6010X | N/A | REDUCED CLOCK & DAY BRILLIANCE | CHECK R1215 | |
GE | 1VCR6010X | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 1VCR6010X | N/A | SNOWY PIX IN PLAYBACK ONLY AUDIO OK | CHECK Q3001 | |
GE | 1VCR6010X | N/A | NO AUTO STOP AT END OF TAPE IN PLAY FAST FOR REW | CHECK/REPLACE Q6008 | |
GE | 1VCR6010X | N/A | WILL NOT RECORD WHEN TIMER IS SET | CHECK/CLEAN ERASE PROTECT SWITCH CONTACTS | |
GE | 1VCR6010X | N/A | UNIT TICKS WHEN PLUGGED IN NO FIP | R1039 | |
GE | 1VCR6010X | N/A | STARTS PLAYING THEN STOPS;COUNTER DOESN'T WORK | CHECK IC1551 | |
GE | 1VCR6010X | N/A | CAPSTAN MOTOR OSCILLATES BACK & FORTH | REPLACE IC2002 | |
GE | 1VCR6010X | N/A | WEAK AUDIO (PLAYBACK ONLY) | CHECK C4014 | |
GE | 1VCR6010X | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FORFEW SECS | CHECK/ REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR6010X | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FOR A FEW S | CHECK / REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR6010X | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 1VCR6010X | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 1VCR6011X | N/A | NO AUTO STOP AT END OF TAPE IN PLAY FAST FOR REW | CHECK/REPLACE Q6008 | |
GE | 1VCR6011X | N/A | EXCESSIVE WOW AND FLUTTER | CHECK/REPLACE C2004 (BREAKING DOWN UNDER LOAD OR HIGH ESR) | |
GE | 1VCR6011X | N/A | NO AUDIO | CHECK/REPLACE Q7010 & Q7002 | |
GE | 1VCR6011X | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 1VCR6011X | N/A | SNOWY PIX IN PLAYBACK ONLY AUDIO OK | CHECK Q3001 | |
GE | 1VCR6011X | N/A | NO COLOR ON PLAYBACK OF PRE-RECORDED TAPES | CHECK/REPLACE IC8101 (MN6163) | |
GE | 1VCR6011X | N/A | INTERMITTENTLY STOPS PLAYING W/KNOWN GOOD TAPE | CHECK Q1552 (SUPPLY PHOTO XSTR) | |
GE | 1VCR6011X | N/A | NO COLOR IN PLAY BACK ONLY | REPLACE IC3502 ON THE HEAD AMP CBA | |
GE | 1VCR6011X | N/A | TOP & BOTTOM 2' OF PIX. OK CENTER SNOWY | CHECK OR REPLACE IC8102 | |
GE | 1VCR6011X | N/A | CAPSTAN MOTOR RUNS ABOUT 8SEC. THEN SHUTS DOWN | CHECK R6070 | |
GE | 1VCR6011X | N/A | WEAK AUDIO (PLAYBACK ONLY) | CHECK C4014 | |
GE | 1VCR6011X | N/A | FAILURE TO PASS LEAKAGE CURRENT HOT CHECK | CHECK OR REPLACE C1005 | |
GE | 1VCR6011X | N/A | CAPSTAN MOTOR OSCILLATES BACK & FORTH | REPLACE IC2002 | |
GE | 1VCR6011X | N/A | DISTORTION OF CASSETTE TRAY SIDE PLATE | CHECK R6070 RC00043,PLOO144,IC6001 | |
GE | 1VCR6011X | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 1VCR6011X | N/A | POWERS UP-LOADS TAPE-NO PLAY,REC,EJECT,FF,REW | REPLACE IC7501 | |
GE | 1VCR6011X | N/A | ALL MODES OPERATIONAL NO FIP DISPLAY | CHECK FILAMENT VOLT.MISSING CHECKPINS7&8 OF T1001 | |
GE | 1VCR6011X | N/A | WILL NOT RECORD WHEN TIMER IS SET | CHECK/CLEAN ERASE PROTECT SWITCH CONTACTS | |
GE | 1VCR6011X | N/A | WHEN PLAY IS PRESSED,VCR RUNS FOR 2-5 SECONDS THEN SHUTS OFF-NEVER SWITCHES FROM TUNER TO VCR-LOADING MOTOR RUNS ON | CHECK/REPLACE MODE SELECT SWITCH | |
GE | 1VCR6011X | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FOR A FEW S | CHECK / REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR6011X | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 1VCR6011X | N/A | POWER SUPPLY TICKS WHEN PLUGGED IN AND ALL SECONDARY VOLTAGES ARE LOW. | CHECK R1002 (680k) FOR OPEN | |
GE | 1VCR6011X | N/A | STARTS PLAYING THEN STOPS;COUNTER DOESN'T WORK | CHECK IC1551 | |
GE | 1VCR6011X | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 1VCR6011X | N/A | NO POWER UP--FIP OK,POWER SUPPLY OK | CK PIN #16 OF IC6001 (4-5V)--IF LOW,CK C6009 | |
GE | 1VCR6011X | N/A | VIDEO FROM RF VIDEO OUTLOOKS SCRAMBLED | CHECK VIDEO SIGNAL ON BOTH SIDES OF C3014 | |
GE | 1VCR6011X | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 1VCR6011X | N/A | REDUCED CLOCK & DAY BRILLIANCE | CHECK R1215 | |
GE | 1VCR6011X | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 1VCR6011X | N/A | NO TRACKING CONTROL MAY LOCK IN BRIEFLY | CHECK/REPLACE IC2002 | |
GE | 1VCR6011X | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FORFEW SECS | CHECK/ REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR6011X | N/A | NO EE OR VV VIDEO AUDIO OK | CHECK/REPLACE IC3101 | |
GE | 1VCR6011X | N/A | SQUEL FROM THE POWER SUPP WHEN PLUGGED IN | CHECK D1023 | |
GE | 1VCR6011X | N/A | UNIT TICKS WHEN PLUGGED IN NO FIP | R1039 | |
GE | 1VCR6011X | N/A | WON'T POWER UP--DRUM RUNS CONTINUOUSLY | REPLACE IC6001 (MN15846VRG) | |
GE | 1VCR6011X | N/A | PUSH PLAY AND TAPE GOES TO REWIND | CHECK/REPLACE END SENSORS | |
GE | 1VCR6013 | N/A | DISTORTION OF CASSETTE TRAY SIDE PLATE | CHECK R6070 RC00043,PLOO144,IC6001 | |
GE | 1VCR6013 | N/A | REDUCED CLOCK & DAY BRILLIANCE | CHECK R1215 | |
GE | 1VCR6013 | N/A | PUSH PLAY AND TAPE GOES TO REWIND | CHECK/REPLACE END SENSORS | |
GE | 1VCR6013 | N/A | SQUEL FROM THE POWER SUPP WHEN PLUGGED IN | CHECK D1023 | |
GE | 1VCR6013 | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 1VCR6013 | N/A | NO COLOR IN PLAY BACK ONLY | REPLACE IC3502 ON THE HEAD AMP CBA | |
GE | 1VCR6013 | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FOR A FEW S | CHECK / REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR6013 | N/A | INTERMITTENTLY STOPS PLAYING W/KNOWN GOOD TAPE | CHECK Q1552 (SUPPLY PHOTO XSTR) | |
GE | 1VCR6013 | N/A | POWER SUPPLY TICKS WHEN PLUGGED IN AND ALL SECONDARY VOLTAGES ARE LOW. | CHECK R1002 (680k) FOR OPEN | |
GE | 1VCR6013 | N/A | UNIT TICKS WHEN PLUGGED IN NO FIP | R1039 | |
GE | 1VCR6013 | N/A | CAPSTAN MOTOR RUNS ABOUT 8SEC. THEN SHUTS DOWN | CHECK R6070 | |
GE | 1VCR6013 | N/A | TOP & BOTTOM 2' OF PIX. OK CENTER SNOWY | CHECK OR REPLACE IC8102 | |
GE | 1VCR6013 | N/A | POWERS UP-LOADS TAPE-NO PLAY,REC,EJECT,FF,REW | REPLACE IC7501 | |
GE | 1VCR6013 | N/A | CAPSTAN MOTOR OSCILLATES BACK & FORTH | REPLACE IC2002 | |
GE | 1VCR6013 | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 1VCR6013 | N/A | WEAK AUDIO (PLAYBACK ONLY) | CHECK C4014 | |
GE | 1VCR6013 | N/A | SNOWY PIX IN PLAYBACK ONLY AUDIO OK | CHECK Q3001 | |
GE | 1VCR6013 | N/A | NO POWER UP--FIP OK,POWER SUPPLY OK | CK PIN #16 OF IC6001 (4-5V)--IF LOW,CK C6009 | |
GE | 1VCR6013 | N/A | STARTS PLAYING THEN STOPS;COUNTER DOESN'T WORK | CHECK IC1551 | |
GE | 1VCR6013 | N/A | VIDEO FROM RF VIDEO OUTLOOKS SCRAMBLED | CHECK VIDEO SIGNAL ON BOTH SIDES OF C3014 | |
GE | 1VCR6013 | N/A | WILL NOT RECORD WHEN TIMER IS SET | CHECK/CLEAN ERASE PROTECT SWITCH CONTACTS | |
GE | 1VCR6013 | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 1VCR6013 | N/A | NO EE OR VV VIDEO AUDIO OK | CHECK/REPLACE IC3101 | |
GE | 1VCR6013 | N/A | AFTER POWER IS APPLIED CAPSTAN SPINS FORFEW SECS | CHECK/ REPLACE Q6003 IN MICROPROCESSOR CIRCUIT | |
GE | 1VCR6013 | N/A | WON'T POWER UP--DRUM RUNS CONTINUOUSLY | REPLACE IC6001 (MN15846VRG) | |
GE | 1VCR6013 | N/A | ALL MODES OPERATIONAL NO FIP DISPLAY | CHECK FILAMENT VOLT.MISSING CHECKPINS7&8 OF T1001 | |
GE | 1VCR6013 | N/A | NO TRACKING CONTROL MAY LOCK IN BRIEFLY | CHECK/REPLACE IC2002 | |
GE | 1VCR6013 | N/A | EXCESSIVE WOW AND FLUTTER | CHECK/REPLACE C2004 (BREAKING DOWN UNDER LOAD OR HIGH ESR) | |
GE | 1VCR6013 | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 1VCR6013 | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 1VCR6013 | N/A | NO AUDIO | CHECK/REPLACE Q7010 & Q7002 | |
GE | 1VCR6013 | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 1VCR6013 | N/A | WHEN PLAY IS PRESSED,VCR RUNS FOR 2-5 SECONDS THEN SHUTS OFF-NEVER SWITCHES FROM TUNER TO VCR-LOADING MOTOR RUNS ON | CHECK/REPLACE MODE SELECT SWITCH | |
GE | 1VCR6013 | N/A | FAILURE TO PASS LEAKAGE CURRENT HOT CHECK | CHECK OR REPLACE C1005 | |
GE | 1VCR6013 | N/A | NO AUTO STOP AT END OF TAPE IN PLAY FAST FOR REW | CHECK/REPLACE Q6008 | |
GE | 1VCR6013 | N/A | NO COLOR ON PLAYBACK OF PRE-RECORDED TAPES | CHECK/REPLACE IC8101 (MN6163) | |
GE | 97100 | N/A | DEW INDICATOR ILLUMINATES AND UNIT SHUTS DOWN | LOOSE CONNECTIONS ONTHE P3 PLUG | |
GE | 97100 | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 97100 | N/A | CAPSTAN AND DRUM MOTORS WILL NOT RUN | CHECK FOR OPEN PR1 ON CAPSTAN/DRUM MOTOR DRIVE CBA | |
GE | 97100 | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 97100 | N/A | DEAD | CHECK/REPLACE Q1001 AND IC1001 | |
GE | 97100 | N/A | LOADING MOTOR SLOW OR SLUGGISH | CHECK/REPLACE C1015 OR C1016 | |
GE | 97100 | N/A | DEAD | CHECK/REPLACE D1014 AND D1010 (MAY CHECK GOOD) | |
GE | 97100 | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 97100 | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 97100 | N/A | NO PLAYBACK VIDEO AND APPEARS THAT HEADS ARE DIRTY | CHECK/REPLACE C3003 FOR SHORT | |
GE | 97100 | N/A | NO PICTURE THRU THE TUNER BUT PLAYS TAPE OK | CHECK/REPLACE IC7001 | |
GE | 97100 | N/A | NO AUDIO FROM TUNER-PLAYBACK AUDIO OK | REPL. IC4001 | |
GE | 97100 | N/A | QUITS PLAYING & SQUELS FROM POWER SUPPLY | CHECK/REPLACE FILTER CAP C1006 | |
GE | 97100 | N/A | NO DRUM/NO CAPSTAN | CHECK PR1 (CIRCUIT PROTECTOR) MOTOR DRIVE BOARD | |
GE | 97100 | N/A | POOR CAPSTAN SPEED OR AUDIO QUIVER ON SP AND CAPSTAN PULSATES BACK AND FORTH ON LP AND SLP | CHECK/REPLACE C1015,C1016,C1018 AND C1019 IN POWER SUPPLY | |
GE | 97100 | N/A | HORZ LINES-DRUM MOTOR RUNNING TOO FAST | REPLACE DD CYL. MOTOR | |
GE | 97100 | N/A | NO FIP LOADING MOTOR ENGAGES OK | CHECK/REPLACE C1020 C1021 L1005 | |
GE | 97100 | N/A | COLOR FADES IN AND OUT | CHECK/REPLACE UPPER CYLINDER UNIT | |
GE | 97100 | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 97100 | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 97100 | N/A | UNIT ACCEPTS TAPE BUT NO OTHER FUNCTIONS WILL WORK | CHECK/REPLACE LED SENSOR LAMP UNIT | |
GE | 97100 | N/A | WOW & FLUTTER MOSTLY IN SLP SPEED | CHECK/REPLACE PINCH ROLLER | |
GE | 97100 | N/A | VCR DOESN'T ERASE OLD AUDIO | CHECK/REPLACE C4023 | |
GE | 97100 | N/A | PICTURE GETS DARKER OR LIGHTER ON PLAYBACK ONLY AND MAY ALSO LOSE COLOR | CHECK/RESOLDER GROUND CONNECTIONS ON R3122 | |
GE | 97100 | N/A | NO PICTURE DURING PLAYBACK-ONLY GREY SCREEN | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97100 | N/A | DRUM SERVO SPEED IS TOO FAST-SLOWING DRUM DOWN BY HAND WILL CAUSE A PICTURE TO APPEAR. | CHECK C2010 AND C2011 FOR LEAKAGE/OPEN/SHORT | |
GE | 97120 | N/A | NO VV OR EE VIDEO AUDIO OK BOTH MODES | CHECK FOR OPEN L3101 COIL | |
GE | 97120 | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 97120 | N/A | TUNER VIDEO PRESENT WHILE PLAYING TAPE | REPLACE IC3101 | |
GE | 97120 | N/A | TUNES CHANNELS MANUALLY BUT WON'T HOLD CHANNEL MEMORY | CHECK/REPLACE IC7603 | |
GE | 97120 | N/A | NO PICTURE THRU THE TUNER BUT PLAYS TAPE OK | CHECK/REPLACE IC7001 | |
GE | 97120 | N/A | UNIT ACCEPTS TAPE BUT NO OTHER FUNCTIONS WILL WORK | CHECK/REPLACE LED SENSOR LAMP UNIT | |
GE | 97120 | N/A | NO DRUM/NO CAPSTAN | CHECK PR1 (CIRCUIT PROTECTOR) MOTOR DRIVE BOARD | |
GE | 97120 | N/A | DEAD | CHECK/REPLACE Q1001 AND IC1001 | |
GE | 97120 | N/A | CAPSTAN AND DRUM MOTORS WILL NOT RUN | CHECK FOR OPEN PR1 ON CAPSTAN/DRUM MOTOR DRIVE CBA | |
GE | 97120 | N/A | VCR DOESN'T ERASE OLD AUDIO | CHECK/REPLACE C4023 | |
GE | 97120 | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 97120 | N/A | WILL NOT LOAD CARRIAGE MOTOR OR TAPE TRANSPORT MOTOR - POWER SHUTS OFF AFTER 5 SECONDS | CHECK/REPLACE Q1203 FOR SHORT | |
GE | 97120 | N/A | WOW & FLUTTER MOSTLY IN SLP SPEED | CHECK/REPLACE PINCH ROLLER | |
GE | 97120 | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 97120 | N/A | WARBLE IN THE AUDIO ON ALL SPEEDS AND SOME COLOR FLASHING IN/OUT | CHECK/REPLACE C1015,C1016,C1018 AND C1019 FOR OPEN | |
GE | 97120 | N/A | DEAD | CHECK/REPLACE D1014 AND D1010 (MAY CHECK GOOD) | |
GE | 97120 | N/A | CASSETTE LOADS OK DD CYLINDER STARTS | REPLACE IC2001 | |
GE | 97120 | N/A | PICTURE GETS DARKER OR LIGHTER ON PLAYBACK ONLY AND MAY ALSO LOSE COLOR | CHECK/RESOLDER GROUND CONNECTIONS ON R3122 | |
GE | 97120 | N/A | COLOR FADES IN AND OUT | CHECK/REPLACE UPPER CYLINDER UNIT | |
GE | 97120 | N/A | NO AUDIO FROM TUNER-PLAYBACK AUDIO OK | REPL. IC4001 | |
GE | 97120 | N/A | NO VIDEO IN VCR MODE AUDIO OK LOSS OF VIDEO Bt. | CHECK AND OR REPLACE L3101 | |
GE | 97120 | N/A | NO PICTURE DURING PLAYBACK-ONLY GREY SCREEN | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97120 | N/A | NO VIDEO - LOOKS LIKE A BAD VIDEO HEAD - AUDIO IS NORMAL | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97120 | N/A | INT. GOOD PIX. / SNOW IN PLAYBACK | CHECK IC2003 | |
GE | 97120 | N/A | NO PLAYBACK VIDEO AND APPEARS THAT HEADS ARE DIRTY | CHECK/REPLACE C3003 FOR SHORT | |
GE | 97120 | N/A | DRUM SERVO SPEED IS TOO FAST-SLOWING DRUM DOWN BY HAND WILL CAUSE A PICTURE TO APPEAR. | CHECK C2010 AND C2011 FOR LEAKAGE/OPEN/SHORT | |
GE | 97120 | N/A | LOADING MOTOR SLOW OR SLUGGISH | CHECK/REPLACE C1015 OR C1016 | |
GE | 97120 | N/A | QUITS PLAYING & SQUELS FROM POWER SUPPLY | CHECK/REPLACE FILTER CAP C1006 | |
GE | 97120 | N/A | SNOWY PIX-TUNING DRIFTS-MAY IMPROVE AFTER WARM | CHECK IC701 | |
GE | 97120 | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 97120 | N/A | HORZ LINES-DRUM MOTOR RUNNING TOO FAST | REPLACE DD CYL. MOTOR | |
GE | 97120 | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER AND CLUTCH ASSY OR IDLER | |
GE | 97120 | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 97120 | N/A | POOR CAPSTAN SPEED OR AUDIO QUIVER ON SP AND CAPSTAN PULSATES BACK AND FORTH ON LP AND SLP | CHECK/REPLACE C1015,C1016,C1018 AND C1019 IN POWER SUPPLY | |
GE | 97120 | N/A | NO VIDEO IN TUNER MODE WITH RF INPUT AUDIO OK | CHECK D4401 OR D4052 | |
GE | 97135 | N/A | NO PICTURE DURING PLAYBACK-ONLY GREY SCREEN | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97135 | N/A | DEAD | CHECK/REPLACE D1014 AND D1010 (MAY CHECK GOOD) | |
GE | 97135 | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 97135 | N/A | LOADING MOTOR SLOW OR SLUGGISH | CHECK/REPLACE C1015 OR C1016 | |
GE | 97135 | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 97135 | N/A | NO PLAYBACK VIDEO AND APPEARS THAT HEADS ARE DIRTY | CHECK/REPLACE C3003 FOR SHORT | |
GE | 97135 | N/A | NO AUDIO FROM TUNER-PLAYBACK AUDIO OK | REPL. IC4001 | |
GE | 97135 | N/A | DEAD | CHECK/REPLACE Q1001 AND IC1001 | |
GE | 97135 | N/A | NO DRUM LOCK - PIX HAS HORZ. LINES | CHECK/REPLACE C2010 AND C2011 FOR LEAKAGE OR A CHANGE IN VALUE. | |
GE | 97135 | N/A | HORZ LINES-DRUM MOTOR RUNNING TOO FAST | REPLACE DD CYL. MOTOR | |
GE | 97135 | N/A | NO PICTURE THRU THE TUNER BUT PLAYS TAPE OK | CHECK/REPLACE IC7001 | |
GE | 97135 | N/A | NO VIDEO - LOOKS LIKE A BAD VIDEO HEAD - AUDIO IS NORMAL | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97135 | N/A | CAPSTAN AND DRUM MOTORS WILL NOT RUN | CHECK FOR OPEN PR1 ON CAPSTAN/DRUM MOTOR DRIVE CBA | |
GE | 97135 | N/A | NO DRUM/NO CAPSTAN | CHECK PR1 (CIRCUIT PROTECTOR) MOTOR DRIVE BOARD | |
GE | 97135 | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 97135 | N/A | DD CYL. MOTOR ROTATES VERY SLOW/ROTATE BACK FORT | CHECK OR REPLACE THE DD CYL. | |
GE | 97135 | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 97135 | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 97135 | N/A | VCR DOESN'T ERASE OLD AUDIO | CHECK/REPLACE C4023 | |
GE | 97135 | N/A | POOR CAPSTAN SPEED OR AUDIO QUIVER ON SP AND CAPSTAN PULSATES BACK AND FORTH ON LP AND SLP | CHECK/REPLACE C1015,C1016,C1018 AND C1019 IN POWER SUPPLY | |
GE | 97135 | N/A | UNIT ACCEPTS TAPE BUT NO OTHER FUNCTIONS WILL WORK | CHECK/REPLACE LED SENSOR LAMP UNIT | |
GE | 97135 | N/A | WOW & FLUTTER MOSTLY IN SLP SPEED | CHECK/REPLACE PINCH ROLLER | |
GE | 97135 | N/A | COLOR FADES IN AND OUT | CHECK/REPLACE UPPER CYLINDER UNIT | |
GE | 97135 | N/A | PICTURE GETS DARKER OR LIGHTER ON PLAYBACK ONLY AND MAY ALSO LOSE COLOR | CHECK/RESOLDER GROUND CONNECTIONS ON R3122 | |
GE | 97135 | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 97135 | N/A | NO DRUM LOCK - PIX HAS HORZ. LINES | CHECK/REPLACE C2010 AND C2011 FOR LEAKAGE OR A CHANGE IN VALUE. | |
GE | 97140 | N/A | UNIT ACCEPTS TAPE BUT NO OTHER FUNCTIONS WILL WORK | CHECK/REPLACE LED SENSOR LAMP UNIT | |
GE | 97140 | N/A | NO AUDIO FROM TUNER-PLAYBACK AUDIO OK | REPL. IC4001 | |
GE | 97140 | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 97140 | N/A | NO DRUM LOCK - PIX HAS HORZ. LINES | CHECK/REPLACE C2010 AND C2011 FOR LEAKAGE OR A CHANGE IN VALUE. | |
GE | 97140 | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 97140 | N/A | WOW & FLUTTER MOSTLY IN SLP SPEED | CHECK/REPLACE PINCH ROLLER | |
GE | 97140 | N/A | TUNES CHANNELS MANUALLY BUT WON'T HOLD CHANNEL MEMORY | CHECK/REPLACE IC7603 | |
GE | 97140 | N/A | WARBLE IN THE AUDIO ON ALL SPEEDS AND SOME COLOR FLASHING IN/OUT | CHECK/REPLACE C1015,C1016,C1018 AND C1019 FOR OPEN | |
GE | 97140 | N/A | COLOR FADES IN AND OUT | CHECK/REPLACE UPPER CYLINDER UNIT | |
GE | 97140 | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 97140 | N/A | NO PICTURE THRU THE TUNER BUT PLAYS TAPE OK | CHECK/REPLACE IC7001 | |
GE | 97140 | N/A | POOR CAPSTAN SPEED OR AUDIO QUIVER ON SP AND CAPSTAN PULSATES BACK AND FORTH ON LP AND SLP | CHECK/REPLACE C1015,C1016,C1018 AND C1019 IN POWER SUPPLY | |
GE | 97140 | N/A | NO DRUM/NO CAPSTAN | CHECK PR1 (CIRCUIT PROTECTOR) MOTOR DRIVE BOARD | |
GE | 97140 | N/A | CAPSTAN AND DRUM MOTORS WILL NOT RUN | CHECK FOR OPEN PR1 ON CAPSTAN/DRUM MOTOR DRIVE CBA | |
GE | 97140 | N/A | PICTURE GETS DARKER OR LIGHTER ON PLAYBACK ONLY AND MAY ALSO LOSE COLOR | CHECK/RESOLDER GROUND CONNECTIONS ON R3122 | |
GE | 97140 | N/A | LOADING MOTOR SLOW OR SLUGGISH | CHECK/REPLACE C1015 OR C1016 | |
GE | 97140 | N/A | VCR DOESN'T ERASE OLD AUDIO | CHECK/REPLACE C4023 | |
GE | 97140 | N/A | DEAD | CHECK/REPLACE D1014 AND D1010 (MAY CHECK GOOD) | |
GE | 97140 | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 97140 | N/A | NO PICTURE DURING PLAYBACK-ONLY GREY SCREEN | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97140 | N/A | NO DRUM LOCK - PIX HAS HORZ. LINES | CHECK/REPLACE C2010 AND C2011 FOR LEAKAGE OR A CHANGE IN VALUE. | |
GE | 97140 | N/A | DEAD | CHECK/REPLACE Q1001 AND IC1001 | |
GE | 97140 | N/A | NO VIDEO - LOOKS LIKE A BAD VIDEO HEAD - AUDIO IS NORMAL | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97140 | N/A | HORZ LINES-DRUM MOTOR RUNNING TOO FAST | REPLACE DD CYL. MOTOR | |
GE | 97140 | N/A | DD CYL. MOTOR ROTATES VERY SLOW/ROTATE BACK FORT | CHECK OR REPLACE THE DD CYL. | |
GE | 97140 | N/A | NO PLAYBACK VIDEO AND APPEARS THAT HEADS ARE DIRTY | CHECK/REPLACE C3003 FOR SHORT | |
GE | 97140 | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 97140 | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 97175 | N/A | LOADING MOTOR SLOW OR SLUGGISH | CHECK/REPLACE C1015 OR C1016 | |
GE | 97175 | N/A | NO VIDEO IN TUNER MODE WITH RF INPUT AUDIO OK | CHECK D4401 OR D4052 | |
GE | 97175 | N/A | UNIT ACCEPTS TAPE BUT NO OTHER FUNCTIONS WILL WORK | CHECK/REPLACE LED SENSOR LAMP UNIT | |
GE | 97175 | N/A | DEAD | CHECK/REPLACE D1014 AND D1010 (MAY CHECK GOOD) | |
GE | 97175 | N/A | NO FIP NO CHANNEL CHANGE | CHECK/ REPLACE R1211 | |
GE | 97175 | N/A | POOR CAPSTAN SPEED OR AUDIO QUIVER ON SP AND CAPSTAN PULSATES BACK AND FORTH ON LP AND SLP | CHECK/REPLACE C1015,C1016,C1018 AND C1019 IN POWER SUPPLY | |
GE | 97175 | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 97175 | N/A | WILL NOT LOAD CARRIAGE MOTOR OR TAPE TRANSPORT MOTOR - POWER SHUTS OFF AFTER 5 SECONDS | CHECK/REPLACE Q1203 FOR SHORT | |
GE | 97175 | N/A | CAPSTAN AND DRUM MOTORS WILL NOT RUN | CHECK FOR OPEN PR1 ON CAPSTAN/DRUM MOTOR DRIVE CBA | |
GE | 97175 | N/A | VCR DOESN'T ERASE OLD AUDIO | CHECK/REPLACE C4023 | |
GE | 97175 | N/A | DEAD | CHECK/REPLACE Q1001 AND IC1001 | |
GE | 97175 | N/A | TUNES CHANNELS MANUALLY BUT WON'T HOLD CHANNEL MEMORY | CHECK/REPLACE IC7603 | |
GE | 97175 | N/A | NO PAUSE,CUE OR REVIEW;PLAY AND RECORD IS OK | CHECK R2031 AND Q3005 | |
GE | 97175 | N/A | NO PLAYBACK VIDEO AND APPEARS THAT HEADS ARE DIRTY | CHECK/REPLACE C3003 FOR SHORT | |
GE | 97175 | N/A | NO PICTURE DURING PLAYBACK-ONLY GREY SCREEN | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97175 | N/A | NO VIDEO - LOOKS LIKE A BAD VIDEO HEAD - AUDIO IS NORMAL | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97175 | N/A | PICTURE GETS DARKER OR LIGHTER ON PLAYBACK ONLY AND MAY ALSO LOSE COLOR | CHECK/RESOLDER GROUND CONNECTIONS ON R3122 | |
GE | 97175 | N/A | DRUM SERVO SPEED IS TOO FAST-SLOWING DRUM DOWN BY HAND WILL CAUSE A PICTURE TO APPEAR. | CHECK C2010 AND C2011 FOR LEAKAGE/OPEN/SHORT | |
GE | 97175 | N/A | COLOR FADES IN AND OUT | CHECK/REPLACE UPPER CYLINDER UNIT | |
GE | 97175 | N/A | QUITS PLAYING & SQUELS FROM POWER SUPPLY | CHECK/REPLACE FILTER CAP C1006 | |
GE | 97175 | N/A | CASSETTE LOADS OK DD CYLINDER STARTS | REPLACE IC2001 | |
GE | 97175 | N/A | NO PICTURE THRU THE TUNER BUT PLAYS TAPE OK | CHECK/REPLACE IC7001 | |
GE | 97250 | N/A | NO DRUM/NO CAPSTAN | CHECK PR1 (CIRCUIT PROTECTOR) MOTOR DRIVE BOARD | |
GE | 97250 | N/A | NO VIDEO IN TUNER MODE WITH RF INPUT AUDIO OK | CHECK D4401 OR D4052 | |
GE | 97250 | N/A | WILL NOT LOAD CARRIAGE MOTOR OR TAPE TRANSPORT MOTOR - POWER SHUTS OFF AFTER 5 SECONDS | CHECK/REPLACE Q1203 FOR SHORT | |
GE | 97250 | N/A | DEAD WITH OPEN FUSE | CHECK D1001,Q1001,R1003 | |
GE | 97250 | N/A | DRUM SERVO SPEED IS TOO FAST-SLOWING DRUM DOWN BY HAND WILL CAUSE A PICTURE TO APPEAR. | CHECK C2010 AND C2011 FOR LEAKAGE/OPEN/SHORT | |
GE | 97250 | N/A | CASSETTE LOADS OK DD CYLINDER STARTS | REPLACE IC2001 | |
GE | 97250 | N/A | CASSETTE LOADS OK UNIT WILL NOT TURN ON | CHECK IC6001 | |
GE | 97250 | N/A | NO AUDIO FROM TUNER-PLAYBACK AUDIO OK | REPL. IC4001 | |
GE | 97250 | N/A | HORZ LINES-DRUM MOTOR RUNNING TOO FAST | REPLACE DD CYL. MOTOR | |
GE | 97250 | N/A | TUNES CHANNELS MANUALLY BUT WON'T HOLD CHANNEL MEMORY | CHECK/REPLACE IC7603 | |
GE | 97250 | N/A | INT. GOOD PIX. / SNOW IN PLAYBACK | CHECK IC2003 | |
GE | 97250 | N/A | WOW & FLUTTER MOSTLY IN SLP SPEED | CHECK/REPLACE PINCH ROLLER | |
GE | 97250 | N/A | LOADING MOTOR SLOW OR SLUGGISH | CHECK/REPLACE C1015 OR C1016 | |
GE | 97250 | N/A | POWER BUTTON INOPERATIVE AFTER WARM UP | CHECK/REPLACE R7639 | |
GE | 97250 | N/A | NO VIDEO - LOOKS LIKE A BAD VIDEO HEAD - AUDIO IS NORMAL | CHECK/REPLACE C3009 FOR SHORT | |
GE | 97250 | N/A | POOR CAPSTAN SPEED OR AUDIO QUIVER ON SP AND CAPSTAN PULSATES BACK AND FORTH ON LP AND SLP | CHECK/REPLACE C1015,C1016,C1018 AND C1019 IN POWER SUPPLY | |
GE | 97250 | N/A | QUITS PLAYING & SQUELS FROM POWER SUPPLY | CHECK/REPLACE FILTER CAP C1006 | |
GE | 97250 | N/A | CAPSTAN AND DRUM MOTORS WILL NOT RUN | CHECK FOR OPEN PR1 ON CAPSTAN/DRUM MOTOR DRIVE CBA | |
GE | 97450 | N/A | TV CHANNEL DRIFTS INTERMITTENTLY | CHECK FL405 (VIDEO DETECT) NEAR IC401 PIN #13 | |
GE | 97515 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | 97515 | N/A | GARBLED AUDIO | CHECK Q0501,R0501,C0502,L0501 | |
GE | 97515 | N/A | SHUTS OFF ON RECORD INTERMITTENT-SOMETIMES VCR WILL KICK THE TAPE OUT. | CHECK/CLEAN THE ERASE PROTECT SWITCH | |
GE | 97515 | N/A | NOISY VIDEO,NOISE BANDS OR STREAKS IN PLAYBACK VIDEO | REMOVE VIDEO HEAD AND INSTALL (2) LOCK WASHERS (210807) ON SCREWS LOCATED UNDER DRUM. | |
GE | 97515 | N/A | AUDIO MISSING IN PLAYBACK--NOT ERASING OLD AUDIO | CHECK IC601 | |
GE | 97515 | N/A | NO VIDEO BUT OSD WORKS NORMALLY | CHECK C317 FOR LEAKAGE | |
GE | 97515 | N/A | CAPSTAN HAS INTERMITTENT SPEED CONTROL | CHECK/RESOLDER CONNECTIONS ON PATH BETWEEN IC601 PIN 26 AND R611 | |
GE | 97515 | N/A | FRONT PANEL LOCKS UP - LOSS OF REMOTE OPERATION - MAY BE INTERMITTENT. | CHECK IC0601-IF THE TYPE NUMBER IS NOT UPD75116CW-091 THEN REPLACE WITH 195143-CHECK ALSO IR RECVR.192280 | |
GE | 97520 | N/A | GARBLED AUDIO-TUNER AUDIO NOT SWITCHING ON P.B. | REPLACE IC4001 | |
GE | 97520 | N/A | SUPPLY REELS START TURNING AS SOON AS UNIT IS PLUGGED IN BUT WILL NOT STAY ON - WILL NOT LOAD CASSETTE | CHECK/REPLACE R1010,D1008 AND C1011 | |
GE | 97520 | N/A | DD CYLINDER RUNS FOR ABOUT 1 MINUTE - CHANNEL NUMBERS CHANGE BUT RECEIVES ONLY SNOW | CHECK/REPLACE D1008 AND R1010 | |
GE | 97520 | N/A | WHEN UNIT IS PLUGGED IN,CAPSTAN RUNS 4-5 SECONDS AND SHUTS DOWN. | CHECK/REPLACE D1008 AND R1010 | |
GE | 97520 | N/A | CAPSTAN MOTOR FLIP FLOPS BACK AND FORTH | CHECK IC8101 | |
GE | 97520 | N/A | CAPSTAN SPINS THEN POWER SHUTS OFF (AT POWER UP) | CHECK IC6001 AND IC6002 | |
GE | 97520 | N/A | CAPSTAN SPINS A FEW TIMES THEN UNIT SHUTS DOWN | CHECK /REPLACE R1010 Q606 | |
GE | 97520 | N/A | TRACKING PROBLEMS IN SP MODE AND 'DONALD DUCK' IN LP AND SLP MODES | CHECK/REPLACE C2023 FOR SHORT | |
GE | 97520 | N/A | DEAD SET AND SHORT ON THE 5 VOLT LINE | CHECK/REPLACE C3137 AND PR1001 | |
GE | 97520 | N/A | TV/VCR FUNCTIONS DOESN'T WORK BUT INDICATOR DOES LIGHT IN THE FIP DISPLAY | CHECK/REPLACE IC7601 | |
GE | 97520 | N/A | ONE TICK FROM POWER SUPPLY-NO DISPLAY-NO POWER | CHECK PR1001,L1003,D1011,C1015 AND C1016 | |
GE | 97520 | N/A | INTERMITTENT LOW NO AUDIO IN E/E PLAYBACK AUD,OK | REPLACE IC4001 | |
GE | 97520 | N/A | SUPPLY REEL STARTS TURNING WHEN UNIT IS PLUGGED | CHECK/REPLACE R1010 D1008 C1011 | |
GE | 97520 | N/A | DRUM MOTOR WILL NOT RUN | CHECK/REPLACE IC2603 | |
GE | 97520 | N/A | WOW & FLUTTER MOSTLY IN SLP SPEED | CHECK/REPLACE PINCH ROLLER | |
GE | 97520 | N/A | NO TUNER VIDEO BUT PLAYS A TAPE OK | CHECK/REPLACE L708,R721 AND C723 | |
GE | 97520 | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 97520 | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 97520 | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 97520 | N/A | DEAD WITH NO BLOWN FUSE OR REGULATOR TRANSISTOR | CHECK/REPLACE D1007 FOR SHORT (6.2V ZENER) | |
GE | 97520 | N/A | SNOW TO NORMAL PIX ON SELF RECORDED TAPES | CHECK CONNECTIONS ON IC2001 (ESPEC. PIN #2) | |
GE | 97520 | N/A | NO TUNER VIDEO BUT PLAYS A TAPE OK | CHECK/REPLACE L708,R721 AND C723 | |
GE | 97520 | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 97520 | N/A | AFTER UNIT RUNS FOR 1/2 TO 1 HOUR, DISPLAY GOES OUT AND VCR LOCKS UP - WON'T TAKE ANY COMMANDS | CHECK/REPLACE IC7502 (MN1280-R) RESET IC | |
GE | 97520 | N/A | PICTURE WOULD GO FROM GOOD TO SNOW-GOOD TO SNOW | CHECK/REPLACE C2023 | |
GE | 97520 | N/A | NO CYLINDER OR CAPSTAN ACTION UNIT SHUTS DOWN | CHECK ICP-F38 (PR206)FOR OPEN CONDITION | |
GE | 97520 | N/A | NO FIP D1205 ON MAIN PWB BEING DRIVEN BEYOND TOL | CHECK C1018 FOR SHORTED CONDITION | |
GE | 97520 | N/A | NO DISPLAY AND NO FUSES BLOWN | CHECK/REPLACE C1015 AND C1016 (330uF @ 16v) | |
GE | 97520 | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 97520 | N/A | FLOURESCENT DISPLAY VERY ERRATIC OR OUT COMPLETELY | CHECK/REPLACE C1004 | |
GE | 97520 | N/A | POWER SUPPLY IS TICKING | CHECK D1007 FOR SHORT OR LEAKAGE | |
GE | 97620 | N/A | NO DISPLAY AND NO FUSES BLOWN | CHECK/REPLACE C1015 AND C1016 (330uF @ 16v) | |
GE | 97655 | N/A | DEAD - NO DISPLAY | CHECK/REPLACE C1015 AND C1016 (RCA P/N# 186753) | |
GE | 97720 | N/A | CAPSTAN SPINS THEN POWER SHUTS OFF (AT POWER UP) | CHECK IC6001 AND IC6002 | |
GE | 97720 | N/A | PICTURE WOULD GO FROM GOOD TO SNOW-GOOD TO SNOW | CHECK/REPLACE C2023 | |
GE | 97720 | N/A | DD CYLINDER RUNS FOR ABOUT 1 MINUTE - CHANNEL NUMBERS CHANGE BUT RECEIVES ONLY SNOW | CHECK/REPLACE D1008 AND R1010 | |
GE | 97720 | N/A | TRACKING PROBLEMS IN SP MODE AND 'DONALD DUCK' IN LP AND SLP MODES | CHECK/REPLACE C2023 FOR SHORT | |
GE | 97720 | N/A | GARBLED AUDIO-TUNER AUDIO NOT SWITCHING ON P.B. | REPLACE IC4001 | |
GE | 97720 | N/A | POWER SUPPLY IS TICKING | CHECK D1007 FOR SHORT OR LEAKAGE | |
GE | 97720 | N/A | TRACKING ADJUSTMENTS | MOST ACCURATELY PERFORMED IN SP MODE. | |
GE | 97720 | N/A | SUPPLY REELS START TURNING AS SOON AS UNIT IS PLUGGED IN BUT WILL NOT STAY ON - WILL NOT LOAD CASSETTE | CHECK/REPLACE R1010,D1008 AND C1011 | |
GE | 97720 | N/A | DEAD SET AND SHORT ON THE 5 VOLT LINE | CHECK/REPLACE C3137 AND PR1001 | |
GE | 97720 | N/A | PIX JITTERS ON SPECIAL EFFECTS | CHECK V-LOCK ADJUSTMENT-WORN HEADS-PG SHIFTERS TR.FIX | |
GE | 97720 | N/A | FLOURESCENT DISPLAY VERY ERRATIC OR OUT COMPLETELY | CHECK/REPLACE C1004 | |
GE | 97720 | N/A | TV/VCR FUNCTIONS DOESN'T WORK BUT INDICATOR DOES LIGHT IN THE FIP DISPLAY | CHECK/REPLACE IC7601 | |
GE | 97720 | N/A | GARBLED AUDIO IN LP AND SLP | CHECK PINCH ROLLER,CLUTCH ASSY.;IDLER | |
GE | 97720 | N/A | DEAD WITH NO BLOWN FUSE OR REGULATOR TRANSISTOR | CHECK/REPLACE D1007 FOR SHORT (6.2V ZENER) | |
GE | 97720 | N/A | WHEN UNIT IS PLUGGED IN,CAPSTAN RUNS 4-5 SECONDS AND SHUTS DOWN. | CHECK/REPLACE D1008 AND R1010 | |
GE | 97720 | N/A | NO COLOR | ADJUST VCO,VXO--CHECK 3.58MHZ,4.2MHZ,629KHZ | |
GE | 97720 | N/A | AFTER UNIT RUNS FOR 1/2 TO 1 HOUR, DISPLAY GOES OUT AND VCR LOCKS UP - WON'T TAKE ANY COMMANDS | CHECK/REPLACE IC7502 (MN1280-R) RESET IC | |
GE | 97720 | N/A | WON'T RECORD -- MANUAL OR OTR | CLEAN OR REPLACE ERASE PROTECT SWITCH | |
GE | 97720 | N/A | ONE TICK FROM POWER SUPPLY-NO DISPLAY-NO POWER | CHECK PR1001,L1003,D1011,C1015 AND C1016 | |
GE | 97720 | N/A | NO TUNER VIDEO BUT PLAYS A TAPE OK | CHECK/REPLACE L708,R721 AND C723 | |
GE | 97720 | N/A | WOW & FLUTTER MOSTLY IN SLP SPEED | CHECK/REPLACE PINCH ROLLER | |
GE | 97720 | N/A | DEAD SET AND SHORT ON THE 5 VOLT LINE | CHECK/REPLACE C3137 AND PR1001 | |
GE | 97720 | N/A | NO DISPLAY AND NO FUSES BLOWN | CHECK/REPLACE C1015 AND C1016 (330uF @ 16v) | |
GE | 97720 | N/A | DRUM MOTOR WILL NOT RUN | CHECK/REPLACE IC2603 | |
GE | 97720 | N/A | NO AUDIO RECORDED AT ANY SPEED | CHECK IC4001 | |
GE | 97885 | N/A | DEAD EXCEPT HI-FI LED'S FLASH | CHECK/REPLACE PR1 ON MAIN POWER SUPPLY | |
GE | 97885 | N/A | PLAYBACK PIX APPEARS SCRAMBLED | CHECK C3106 | |
GE | 97885 | N/A | TUNER/PLAYBACK VIDEO FLUTTERS OR FLASHES | CHECK/REPLACE C1414,C1415,C1416 ON DIGITAL POWER SUPPLY-LOCATED BEHIND VIDEO DRUM AREA. | |
GE | 97885 | N/A | TUNER/PLAYBACK VIDEO FLUTTERS OR FLASHES | CHECK/REPLACE C1414,C1415,C1416 ON DIGITAL POWER SUPPLY-LOCATED BEHIND VIDEO DRUM AREA. | |
GE | 97885 | N/A | DEAD EXCEPT HI-FI LED'S FLASH | CHECK/REPLACE PR1 ON MAIN POWER SUPPLY | |
GE | 97885 | N/A | NO PLAYBACK CHROMA -MAY BE INTERMITTENT | CHECK/REPLACE IC8301-MAY BE THERMAL (AN3494NK) | |
GE | 97885 | N/A | NO PLAYBACK CHROMA -MAY BE INTERMITTENT | CHECK/REPLACE IC8301-MAY BE THERMAL (AN3494NK) | |
GE | VG2001 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG2001 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG2001 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG2001 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG2001 | N/A | NO TUNER OPERATION--PLAYS TAPES OK | CHECK Q7 ON TUNER/IF BOARD | |
GE | VG2001 | N/A | SLP SPEED VERY SLOW - WON'T TRACK SP AND LP GOOD | CHECK/REPLACE DRUM ASSEMBLY OR STATOR UNIT | |
GE | VG2001 | N/A | NO TUNER - DRUM WILL NOT ROTATE - WON'T EJECT | CHECK/REPLACE Q108 | |
GE | VG2001 | N/A | PRESS PLAY AND UNIT SHUTS OFF IN 5 SECONDS | CLEAN DRIED MOLYTONE FOR GEAR DRIVE ASSY.-LUBRICATE | |
GE | VG2001 | N/A | WON'T ACCEPT TAPE - IF MANUALLY LOADED, IT WON'T PLAY,REW, OR FAST FORWARD | CHECK/REPLACE D112 | |
GE | VG2001 | N/A | NO CAPSTAN MOTOR IN ANY FUNCTION OR MODE | CHECK/REPLACE R230 OPEN (MAY CHECK OK IN CIRCUIT) | |
GE | VG2001 | N/A | DEAD - NO DISPLAY OR FUNCTIONS | CHECK/REPLACE C102 | |
GE | VG2001 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG2001 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG2001 | N/A | VCR IS SQUEALING WHILE PLAYING OR RECORDING - NOT PLAYING OR REWINDING TO END OF TAPE - UNIT MAY STOP INTERMITTENTLY | CHECK/REPLACE TAKE-UP REEL (P/N# 207491) AND SUPPLY REEL (P/N# 207492) - BOTH PARTS HAVE BEEN REVISED | |
GE | VG2001 | N/A | PLAYS AND RECORDS BAD IN SLP ONLY | CHECK/REPLACE CAPSTAN MOTOR | |
GE | VG2001 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG2001 | N/A | POOR AUDIO--AUDIO QUIVER--ESPECIALLY ON SLP | REPLACE CLUTCH ASSEMBLY (861-646-04) | |
GE | VG2001 | N/A | MOTOR NOISE IN E-E WHEN LOADING OR UNLOADING A TAPE IN PB | CHECK/RESOLDER CONNECTIONS ON C112 | |
GE | VG2001 | N/A | WARBLE IN THE AUDIO ON ALL SPEEDS | CHECK/RESOLDER CONNECTIONS ON C112 | |
GE | VG2001 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG2001 | N/A | NO CAPSTAN MOTOR IN ANY FUNCTION OR MODE | CHECK/REPLACE R230 OPEN (MAY CHECK OK IN CIRCUIT) | |
GE | VG2007 | N/A | SET TURNS ON/OFF - AS TAPE LOADS,DRUM RUNS TO FAST THEN SHUTS DOWN | CHECK/RESOLDER CONNECTIONS ON CN202 AND CN205 (SCRAPE PINS CLEAN) | |
GE | VG2007 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG2007 | N/A | CASSETTE WILL NOT EJECT - NO FUNCTIONS | CHECK/REPLACE JOINT GEAR (65203-605-330) LOCATED ON THE RIGHT SIDE OF THE CARRIAGE (IF NOT METAL,REPLACE) | |
GE | VG2007 | N/A | LOADS TAPE THEN UNLOADS - CAPSTAN AND DRUM MOTORS DON'T RUN | CHECK/REPLACE Q109 | |
GE | VG2007 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG2007 | N/A | LINES IN THE VIDEO DURING E-E MODE (TUNER MODE) | CHECK/RESOLDER CONNECTIONS ON COAX CABLE FROM THE TUNER TO THE RF CONVERTER | |
GE | VG2007 | N/A | INTERFERENCE IN PIX - LOOKS LIKE MOTOR NOISE - NOISE STOPS WHEN CAPSTAN MOTOR STOPS | CHECK/REPLACE C112 FOR OPEN | |
GE | VG2007 | N/A | LOADS TAPE THEN UNLOADS - CAPSTAN AND DRUM MOTORS DON'T RUN | CHECK/REPLACE Q109 | |
GE | VG2007 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG2007 | N/A | CASSETTE WILL NOT EJECT - NO FUNCTIONS | CHECK/REPLACE JOINT GEAR (65203-605-330) LOCATED ON THE RIGHT SIDE OF THE CARRIAGE (IF NOT METAL,REPLACE) | |
GE | VG2007 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG2007 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG2007 | N/A | UNIT LOADS VERY SLOW | CHECK/REPLACE C102 | |
GE | VG2007 | N/A | VCR IS SQUEALING WHILE PLAYING OR RECORDING - NOT PLAYING OR REWINDING TO END OF TAPE - UNIT MAY STOP INTERMITTENTLY | CHECK/REPLACE TAKE-UP REEL (P/N# 207491) AND SUPPLY REEL (P/N# 207492) - BOTH PARTS HAVE BEEN REVISED | |
GE | VG2007 | N/A | RADIATED INTERFERENCE | CHECK/REPLACE C112 | |
GE | VG2007 | N/A | NO FLOURESCENT DISPLAY | CHECK/REPLACE R102,R103,R116 AND ZD101 | |
GE | VG2007 | N/A | NO FLOURESCENT DISPLAY | CHECK/REPLACE R102,R103,R116 AND ZD101 | |
GE | VG2007 | N/A | LOADS SLOWLY | CHECK/REPLACE C102 | |
GE | VG2007 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG2007 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG2010 | N/A | DEAD - NO POWER | CHECK/REPLACE D1103 AND D1104 | |
GE | VG2010 | N/A | NO DISPLAY | CHECK/REPLACE D105 AND D106 | |
GE | VG2010 | N/A | TAPE WON'T LOAD | CHECK/REPLACE D111 AND D112 | |
GE | VG2010 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG2010 | N/A | LOUD GRINDING NOISE IN FAST FORWARD OR REWIND | CHECK/REPLACE DRIVE CLUTCH WHEEL (210841) | |
GE | VG2010 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG2010 | N/A | TAPE WON'T LOAD | CHECK/REPLACE D111 AND D112 | |
GE | VG2010 | N/A | WILL FF AND REW BUT WILL NOT PLAY - EATS TAPES WHEN EJECTED | CHECK/REPLACE D108, D109, D110 | |
GE | VG2010 | N/A | VCR IS SQUEALING WHILE PLAYING OR RECORDING - NOT PLAYING OR REWINDING TO END OF TAPE - UNIT MAY STOP INTERMITTENTLY | CHECK/REPLACE TAKE-UP REEL (P/N# 207491) AND SUPPLY REEL (P/N# 207492) - BOTH PARTS HAVE BEEN REVISED | |
GE | VG2010 | N/A | LOUD GRINDING NOISE IN FAST FORWARD OR REWIND | CHECK/REPLACE DRIVE CLUTCH WHEEL (210841) | |
GE | VG2010 | N/A | CAPSTAN WON'T RUN IN THE PLAY MODE - REW/FF ARE OK | CHECK/REPLACE Q102 | |
GE | VG2010 | N/A | NO DISPLAY | CHECK/REPLACE D105 AND D106 | |
GE | VG2010 | N/A | DEAD | CHECK/REPLACE D1103 AND D1104 | |
GE | VG2010 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG2010 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG2010 | N/A | WILL FF AND REW BUT WILL NOT PLAY - EATS TAPES WHEN EJECTED | CHECK/REPLACE D108, D109, D110 | |
GE | VG2010 | N/A | DEAD - NO POWER | CHECK/REPLACE D1103 AND D1104 | |
GE | VG2010 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG2010 | N/A | CAPSTAN MOTOR WON'T RUN | CHECK/REPLACE D108,D109,D110 | |
GE | VG2011 | N/A | CAPSTAN MOTOR RUNS AT ERRATIC JERKING SPEED-IC2502 GETS HOT | CHECK/REPLACE OPEN FG HEAD ON CAPSTAN STATOR UNIT | |
GE | VG2013 | N/A | CAPSTAN MOTOR RUNS AT ERRATIC JERKING SPEED-IC2502 GETS HOT | CHECK/REPLACE OPEN FG HEAD ON CAPSTAN STATOR UNIT | |
GE | VG2014 | N/A | RIGHT CASSETTE HOLDER LOOSE AND GEARS MIS-ALIGNED | INSTALL TAB SUPPORT SPRING (210652) | |
GE | VG2016 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG2016 | N/A | NO DISPLAY | CHECK/REPLACE D105 AND D106 | |
GE | VG2016 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG2016 | N/A | WILL FF AND REW BUT WILL NOT PLAY - EATS TAPES WHEN EJECTED | CHECK/REPLACE D108, D109, D110 | |
GE | VG2016 | N/A | VCR IS SQUEALING WHILE PLAYING OR RECORDING - NOT PLAYING OR REWINDING TO END OF TAPE - UNIT MAY STOP INTERMITTENTLY | CHECK/REPLACE TAKE-UP REEL (P/N# 207491) AND SUPPLY REEL (P/N# 207492) - BOTH PARTS HAVE BEEN REVISED | |
GE | VG2016 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG2016 | N/A | DISPLAY AND TUNER OK BUT TRANSPORT WON'T RUN | CHECK/REPLACE IC1101 | |
GE | VG2016 | N/A | TAPE WON'T LOAD | CHECK/REPLACE D111 AND D112 | |
GE | VG2016 | N/A | UNIT DEAD - NO CASSETTE IN UNIT BUT CASSETTE INDICATOR IS ON | CHECK/REPLACE R637 (4.7k) | |
GE | VG2016 | N/A | TAPE WON'T LOAD | CHECK/REPLACE D111 AND D112 | |
GE | VG2016 | N/A | LOUD GRINDING NOISE IN FAST FORWARD OR REWIND | CHECK/REPLACE DRIVE CLUTCH WHEEL (210841) | |
GE | VG2016 | N/A | NO DISPLAY | CHECK/REPLACE D105 AND D106 | |
GE | VG2016 | N/A | E-E AND PLAYBACK VIDEO LEVEL LOW AND DISTORTED - VIDEO VERY WASHED OUT | CHECK/REPLACE IC302 | |
GE | VG2016 | N/A | CAPSTAN MOTOR WON'T RUN | CHECK/REPLACE D108,D109,D110 | |
GE | VG2016 | N/A | CAPSTAN SPEED IS TOO SLOW | CHECK/REPLACE IC201 | |
GE | VG2016 | N/A | WILL FF AND REW BUT WILL NOT PLAY - EATS TAPES WHEN EJECTED | CHECK/REPLACE D108, D109, D110 | |
GE | VG2016 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG2016 | N/A | NO DISPLAY AND NO FUNCTIONS WORK | CHECK/REPLACE R609 | |
GE | VG2016 | N/A | LOUD GRINDING NOISE IN FAST FORWARD OR REWIND | CHECK/REPLACE DRIVE CLUTCH WHEEL (210841) | |
GE | VG2016 | N/A | DEAD - NO POWER | CHECK/REPLACE D1103 AND D1104 | |
GE | VG2016 | N/A | CAPSTAN MOTOR WON'T RUN | CHECK/REPLACE D108,D109,D110 | |
GE | VG2016 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG2016 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG2016 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG2016 | N/A | DEAD - NO POWER | CHECK/REPLACE D1103 AND D1104 | |
GE | VG2021 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 212502) | |
GE | VG2021 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (220uF @ 16v - P/N# 189978) | |
GE | VG2021 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG2030 | N/A | UNSTABLE OR WAVING PICTURE WHEN USING THE VCR'S RF CONVERTER | CHANGE R7005 TO A 200 1/4w. RESISTOR | |
GE | VG2030 | N/A | TAPE SLACK OCCURS WHEN GOING FROM F/F OR REW TO STOP MODE | CHECK/REPLACE 'T' BRAKE SPRING (P/N# 228959) | |
GE | VG2035 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 220990) | |
GE | VG2056 | N/A | NO DISPLAY - VCR WORKS FINE OTHERWISE | CHECK/REPLACE R62 (18?@ 1/10w) | |
GE | VG2058 | N/A | VCR ONLY RECORDS NOISE ON CHANNELS ABOVE 13 WHEN USING THE VCR PLUS MODE | CHECK/REPLACE IC601 (P/N# 235539) | |
GE | VG2058 | N/A | NO DISPLAY - VCR WORKS FINE OTHERWISE | CHECK/REPLACE R62 (18?@ 1/10w) | |
GE | VG4005 | N/A | DISTORTED E-E AUDIO/VIDEO - VCR SHUTSDOWN WHEN GOING TO PLAY MODE | CHECK/REPLACE C102 IN POWER SUPPLY | |
GE | VG4005 | N/A | AUDIO AND VIDEO ARE DISTORTED IN THE E-E MODE AND VCR SHUTS DOWN WHEN PRESSING PLAY | CHECK/REPLACE C102 (330uF @ 35v) | |
GE | VG4005 | N/A | NO DISPLAY BUT UNIT DOES OPERATE FINE | CHECK/REPLACE R102 AND R103 | |
GE | VG4005 | N/A | WON'T RECORD VIDEO | CHECK/REPLACE C331 IN Y/C CIRCUIT | |
GE | VG4005 | N/A | SLOW TURNING DRUM - INTERMITTENT FUNCTIONS | CHECK/REPLACE C102 (3300uF @ 25v) | |
GE | VG4005 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG4005 | N/A | PIX OK - SOUND OK ON VOICE BUT DRAGS ON MUSIC | CHECK ALIGNMENT OF AUDIO/CTRL HEAD (HORZ 2 POSITION) | |
GE | VG4005 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG4005 | N/A | IN THE PLAY MODE,DRUM SPEED INCREASES AND SHUTS DOWN | CHECK/REPLACE INTERMITTENT MOTOR STATOR (T305) | |
GE | VG4005 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG4005 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG4005 | N/A | DRUM RUN-AWAY | CHECK/RESOLDER CONNECTIONS ON STAPLES OR JUMPERS LOCATED ON DRUM STATOR UNIT | |
GE | VG4005 | N/A | VCR IS SQUEALING WHILE PLAYING OR RECORDING - NOT PLAYING OR REWINDING TO END OF TAPE - UNIT MAY STOP INTERMITTENTLY | CHECK/REPLACE TAKE-UP REEL (P/N# 207491) AND SUPPLY REEL (P/N# 207492) - BOTH PARTS HAVE BEEN REVISED | |
GE | VG4005 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG4005 | N/A | UNIT SHUTS DOWN WHEN PLAY OR RECORD MODE IS SELECTED | CHECK/REPLACE DRUM MOTOR STATOR ASSEMBLY | |
GE | VG4005 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG4005 | N/A | TAPE LOADS BUT NO OTHER FUNCTIONS WORK - DISPLAY OK | CHECK/REPLACE C103 (3300uF @ 35v) | |
GE | VG4005 | N/A | LP AND SLP RECORDING PLAYED BACK SNOW ONLY - SP IS FINE - LOOKS LIKE A BAD HEAD | CHECK/REPLACE IC6101 | |
GE | VG4011 | N/A | MICROPROCESSOR LOCK-UP OR IMPROPER RESET | CHANGE C6001 TO A 1uF @ 50v | |
GE | VG4011 | N/A | MICROPROCESSOR LOCK-UP OR IMPROPER RESET | CHANGE C6001 TO A 1uF @ 50v | |
GE | VG4011 | N/A | RIGHT CASSETTE HOLDER LOOSE AND GEARS MIS-ALIGNED | INSTALL TAB SUPPORT SPRING (210652) | |
GE | VG4011 | N/A | NO AUDIO OR VIDEO FROM TUNER OR TAPE | CHECK/REPLACE Q1201 | |
GE | VG4012 | N/A | RIGHT CASSETTE HOLDER LOOSE AND GEARS MIS-ALIGNED | INSTALL TAB SUPPORT SPRING (210652) | |
GE | VG4014 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 212502) | |
GE | VG4014 | N/A | AUDIO BUT NO PICTURE IN PLAYBACK MODE | CHECK/REPLACE D303 AND D306 FOR OPEN | |
GE | VG4014 | N/A | NO CHROMA ON RECORD - WILL PLAYBACK COLOR FROM A KNOWN GOOD TAPE | CHECK/REPLACE IC302 | |
GE | VG4014 | N/A | INTERMITTENTLY EATS TAPES OR DOESN'T WANT TO LOAD TAPES OR MAY SHUTDOWN | CHECK/REPLACE MODE SELECT SWITCH | |
GE | VG4014 | N/A | UNIT ACCEPTS TAPE BUT WILL NOT LOAD OR UNLOAD TAPE AROUND HEADS | CHECK/REPLACE IC101 | |
GE | VG4014 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (220uF @ 16v - P/N# 189978) | |
GE | VG4014 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 212502) | |
GE | VG4014 | N/A | DEAD WITH OR WITHOUT FUSE BLOWN | CHECK/REPLACE Q1,Q2 AND D02 IN POWER SUPPLY | |
GE | VG4014 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4014 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4014 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (220uF @ 16v - P/N# 189978) | |
GE | VG4014 | N/A | ERRATIC OPERATION - MAY LOAD TAPE BUT NOT EJECT OR JUMP OUT OF TIME ON LOAD/UNLOADING OF TAPE | CHECK/REPLACE CAM SWITCH (P/N# 212516) | |
GE | VG4016 | N/A | VCR IS SQUEALING WHILE PLAYING OR RECORDING - NOT PLAYING OR REWINDING TO END OF TAPE - UNIT MAY STOP INTERMITTENTLY | CHECK/REPLACE TAKE-UP REEL (P/N# 207491) AND SUPPLY REEL (P/N# 207492) - BOTH PARTS HAVE BEEN REVISED | |
GE | VG4016 | N/A | CAPSTAN MOTOR WON'T RUN | CHECK/REPLACE D108,D109,D110 | |
GE | VG4016 | N/A | PRE-RECORDED TAPES PLAY OK BUT TAPES RECORDED ON ANOTHER VCR HAVE TRACKING LINES IN PICTURE | CHECK/REPLACE IC201 | |
GE | VG4016 | N/A | CAPSTAN MOTOR WON'T RUN IN PLAY MODE | CHECK/REPLACE D111 | |
GE | VG4016 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG4016 | N/A | WILL FF AND REW BUT WILL NOT PLAY - EATS TAPES WHEN EJECTED | CHECK/REPLACE D108, D109, D110 | |
GE | VG4016 | N/A | TAPE WON'T LOAD | CHECK/REPLACE D111 AND D112 | |
GE | VG4016 | N/A | NO DISPLAY | CHECK/REPLACE D105 AND D106 | |
GE | VG4016 | N/A | ALL TAPES ENTER PLAY MODE - PRESSING THE RECORD BUTTON CAUSES TAPES TO EJECT | CHECK/REPLACE R645 OPEN | |
GE | VG4016 | N/A | INTERMITTENT REWIND AND MAKING A LOUD NOISE | CHECK FOR MISSING WASHER ON CLUTCH ASSY. (#956) | |
GE | VG4016 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG4016 | N/A | AS SOON AS AC IS PLUGGED IN, CAPSTAN MOTOR AND LOADING MOTOR TURN IN REVERSE | CHECK/REPLACE START AND END SENSORS | |
GE | VG4016 | N/A | LOUD GRINDING NOISE IN FAST FORWARD OR REWIND | CHECK/REPLACE DRIVE CLUTCH WHEEL (210841) | |
GE | VG4016 | N/A | TAPE WON'T LOAD | CHECK/REPLACE D111 AND D112 | |
GE | VG4016 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG4016 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG4016 | N/A | DEAD SET | CHECK/REPLACE XT601 | |
GE | VG4016 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG4016 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG4016 | N/A | LOADS TAPE THEN VCR SHUTS OFF - LOOKS LIKE MODE SELECT SWITCH OR SYSCON PROBLEM | CHECK/REPLACE SERVO IC (KA8319) P/N# 207792 | |
GE | VG4016 | N/A | VCR LOOSES CLOCK AND POWER INTERMITTENTLY | CHECK/REPLACE D602 AND IC602 | |
GE | VG4016 | N/A | CAPSTAN MOTOR WON'T RUN | CHECK/REPLACE D108,D109,D110 | |
GE | VG4016 | N/A | NO AUDIO ON PLAYBACK - TUNER AUDIO IS NORMAL | CHECK/REPLACE R514 | |
GE | VG4016 | N/A | NO DISPLAY | CHECK/REPLACE D105 AND D106 | |
GE | VG4016 | N/A | LOUD GRINDING NOISE IN FAST FORWARD OR REWIND | CHECK/REPLACE DRIVE CLUTCH WHEEL (210841) | |
GE | VG4016 | N/A | VERTICAL JITTER ON PLAYBACK OF ALL TAPES | CHECK/REPLACE IC302 | |
GE | VG4016 | N/A | DEAD - NO POWER | CHECK/REPLACE D1103 AND D1104 | |
GE | VG4016 | N/A | DEAD - NO POWER | CHECK/REPLACE D1103 AND D1104 | |
GE | VG4018 | N/A | CLOCK LOSES ABOUT 15 MINUTES PER DAY | CHECK FOR A SOLDER BRIDGE BETWEEN PINS 23 AND 24 OF IC751 | |
GE | VG4018 | N/A | WON'T ALWAYS LOAD TAPE - TAPE SPEED TOO FAST IN SP MODE - WHEN GOING TO EJECT,MACHINE SHUTS DOWN INSTEAD | CHECK/REPLACE CAPSTAN MOTOR | |
GE | VG4018 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG4018 | N/A | VERY NOISY ON REWIND/FAST FORWARD/EJECT | LUBRICATE CAPSTAN MOTOR SHAFT | |
GE | VG4018 | N/A | MISCELLANEOUS CONTROL PROBLEMS - ERRATIC OPERATIONS - DAMAGES TAPE - WON'T EJECT | CLEAN EXCESSIVE FLUX FROM THE PINS OF IC751 AND SURROUNDING AREA | |
GE | VG4018 | N/A | WON'T ALWAYS LOAD TAPE - TAPE SPEED TOO FAST IN SP MODE - WHEN GOING TO EJECT,MACHINE SHUTS DOWN INSTEAD | CHECK/REPLACE CAPSTAN MOTOR | |
GE | VG4018 | N/A | NO COLOR ON PLAYBACK | HARDWIRE P6833/P6233 PIN 1 | |
GE | VG4018 | N/A | INTERMITTENT LOADING - LOUD NOISE AND TAPE IN LIGHT STAYS ON WITH NO CASSETTE | CHECK/RESOLDER CONNECTIONS ON END SENSORS | |
GE | VG4019 | N/A | VCR PLUS CHANNEL GUIDE SETUP DOES NOT STORE SOME CHANNEL NUMBERS | CHECK TO SEE IF PIN 7 OF IC604 IS GROUNDED-CHECK PINS 5&6 OF IC604 FOR 4vpp-IF LOW CHECK R646,653,647,652 & IC601,2,4 | |
GE | VG4019 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (220uF @ 16v - P/N# 189978) | |
GE | VG4019 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4019 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (220uF @ 16v - P/N# 189978) | |
GE | VG4019 | N/A | ERRATIC OPERATION - MAY LOAD TAPE BUT NOT EJECT OR JUMP OUT OF TIME ON LOAD/UNLOADING OF TAPE | CHECK/REPLACE CAM SWITCH (P/N# 212516) | |
GE | VG4019 | N/A | DEAD WITH OR WITHOUT FUSE BLOWN | CHECK/REPLACE Q1,Q2 AND D02 IN POWER SUPPLY | |
GE | VG4019 | N/A | NO CHROMA ON RECORD - WILL PLAYBACK COLOR FROM A KNOWN GOOD TAPE | CHECK/REPLACE IC302 | |
GE | VG4019 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4019 | N/A | INTERMITTENTLY EATS TAPES OR DOESN'T WANT TO LOAD TAPES OR MAY SHUTDOWN | CHECK/REPLACE MODE SELECT SWITCH | |
GE | VG4019 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 212502) | |
GE | VG4019 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 212502) | |
GE | VG4019 | N/A | AUDIO BUT NO PICTURE IN PLAYBACK MODE | CHECK/REPLACE D303 AND D306 FOR OPEN | |
GE | VG4025 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 218966) | |
GE | VG4025 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (470uF @ 16v - P/N# 176251) | |
GE | VG4025 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4029 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 218966) | |
GE | VG4029 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4029 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (470uF @ 16v - P/N# 176251) | |
GE | VG4030 | N/A | TAPE SLACK OCCURS WHEN GOING FROM F/F OR REW TO STOP MODE | CHECK/REPLACE 'T' BRAKE SPRING (P/N# 228959) | |
GE | VG4030 | N/A | UNSTABLE OR WAVING PICTURE WHEN USING THE VCR'S RF CONVERTER | CHANGE R7005 TO A 200 1/4w. RESISTOR | |
GE | VG4031 | N/A | TAPE SLACK OCCURS WHEN GOING FROM F/F OR REW TO STOP MODE | CHECK/REPLACE 'T' BRAKE SPRING (P/N# 228959) | |
GE | VG4031 | N/A | UNSTABLE OR WAVING PICTURE WHEN USING THE VCR'S RF CONVERTER | CHANGE R7005 TO A 200 1/4w. RESISTOR | |
GE | VG4032 | N/A | TAPE SLACK OCCURS WHEN GOING FROM F/F OR REW TO STOP MODE | CHECK/REPLACE 'T' BRAKE SPRING (P/N# 228959) | |
GE | VG4032 | N/A | UNSTABLE OR WAVING PICTURE WHEN USING THE VCR'S RF CONVERTER | CHANGE R7005 TO A 200 1/4w. RESISTOR | |
GE | VG4033 | N/A | UNSTABLE OR WAVING PICTURE WHEN USING THE VCR'S RF CONVERTER | CHANGE R7005 TO A 200 1/4w. RESISTOR | |
GE | VG4033 | N/A | TAPE SLACK OCCURS WHEN GOING FROM F/F OR REW TO STOP MODE | CHECK/REPLACE 'T' BRAKE SPRING (P/N# 228959) | |
GE | VG4035 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 220990) | |
GE | VG4036 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 220990) | |
GE | VG4038 | N/A | FRONT PANEL TRACKING BUTTONS INOPERATIVE | THESE BUTTONS CANNOT BE HELD DOWN - THEY HAVE TO BE PRESSED AND RELEASED REPEATEDLY | |
GE | VG4038 | N/A | WHITE DOT OR TADPOLE NOISE IN THE PLAYBACK VIDEO EARLY PROD. BOARDS MRK'D (20194390.00.000) | INSTALL KIT (P/N# 229296) | |
GE | VG4038 | N/A | VCR IS COMPLETELY DEAD | CHECK/REPLACE DP026 AND DP027 - MOVE ANODE OF DP027 TO THE OPPOSITE END OF LP002 - INSTALL KIT (P/N# 231734) | |
GE | VG4038 | N/A | DRUM DOES NOT ROTATE | CHECK FOR DUST AROUND THE POST OF THE OPTICAL PICKUP ON THE DRUM MOTOR FLYWHEEL - ANY BUILD UP CAN BE A PROBLEM | |
GE | VG4038 | N/A | NO COLOR IN LP SEARCH | THIS IS NOT A MALFUNCTION BUT A DESIGN CHARACTERISTIC | |
GE | VG4038 | N/A | DEAD SET | CHECK/REPLACE MODIFICATION KIT (P/N# 231734) | |
GE | VG4038 | N/A | ROLLING/FLOATING VERTICAL BAR WHEN PLAYING BACK SELF RECORDED TAPES - EARLY PROD. BOARDS MRK'D (20194390.00.000) | INSTALL KIT (P/N# 229296) | |
GE | VG4039 | N/A | FRONT PANEL TRACKING BUTTONS INOPERATIVE | THESE BUTTONS CANNOT BE HELD DOWN - THEY HAVE TO BE PRESSED AND RELEASED REPEATEDLY | |
GE | VG4039 | N/A | NO COLOR IN LP SEARCH | THIS IS NOT A MALFUNCTION BUT A DESIGN CHARACTERISTIC | |
GE | VG4039 | N/A | FLUORESCENT DISPLAY FLASHES INTERMITTENTLY ONLY WHEN THE UNIT IS IN THE OFF MODE - MAY GO FROM TIME DISPLAY TO --:-- | ADD INTERRUPT CBA (P/N# 233212) | |
GE | VG4039 | N/A | VCR IS COMPLETELY DEAD | CHECK/REPLACE DP026 AND DP027 - MOVE ANODE OF DP027 TO THE OPPOSITE END OF LP002 - INSTALL KIT (P/N# 231734) | |
GE | VG4039 | N/A | DRUM DOES NOT ROTATE | CHECK FOR DUST AROUND THE POST OF THE OPTICAL PICKUP ON THE DRUM MOTOR FLYWHEEL - ANY BUILD UP CAN BE A PROBLEM | |
GE | VG4039 | N/A | WHITE DOT OR TADPOLE NOISE IN THE PLAYBACK VIDEO EARLY PROD. BOARDS MRK'D (20194390.00.000) | INSTALL KIT (P/N# 229296) | |
GE | VG4039 | N/A | ROLLING/FLOATING VERTICAL BAR WHEN PLAYING BACK SELF RECORDED TAPES - EARLY PROD. BOARDS MRK'D (20194390.00.000) | INSTALL KIT (P/N# 229296) | |
GE | VG4039 | N/A | DEAD SET | CHECK/REPLACE MODIFICATION KIT (P/N# 231734) | |
GE | VG4039 | N/A | FLUORESCENT DISPLAY FLASHES INTERMITTENTLY ONLY WHEN THE UNIT IS IN THE OFF MODE - MAY GO FROM TIME DISPLAY TO --:-- | CHECK/REPLACE IT001 (P/N# 229330) | |
GE | VG4055 | N/A | DISTORTED/GARBLED LINEAR AUDIO DURING SLP PLAYBACK ONLY | CHECK/REPLACE IC601 (P/N# 231932) WITH NEW TYPE | |
GE | VG4055 | N/A | WAVY PICTURE ON PLAYBACK OR SQUEAL FROM CAPSTAN MOTOR | CHECK/REPLACE FELT PAD UNDER THE CAPSTAN MOTOR (P/N 233964) | |
GE | VG4055 | N/A | VCR TURNS OFF AFTER POWERED ON OR UNIT HAS EXCESSIVE DRUM SPEED | CHECK/RESOLDER CONNECTIONS ON 6 PIN POWER CONNECTOR TO THE DRUM MOTOR -- THIS CONNECTOR IS SURFACE MOUNTED | |
GE | VG4055 | N/A | CASSETTE TAPE DOES NOT SLOW DOWN AT THE END OF HIGH SPEED REWIND | CHECK/REPLACE DIODE LOCATED ON THE EMITTER LEG OF Q202 | |
GE | VG4056 | N/A | NO DISPLAY - VCR WORKS FINE OTHERWISE | CHECK/REPLACE R62 (18?@ 1/10w) | |
GE | VG4058 | N/A | VCR SHUTS OFF AFTER THE TAPE IS LOADED | CHECK/REPLACE SW601 (P/N# 229178) | |
GE | VG4200 | N/A | NO AUDIO FROM TUNER OR LINE | CHECK/REPLACE R1205,D1007,C1014 AND C1021 | |
GE | VG4202 | N/A | INTERMITTENT AUDIO OR VERY LOW AUDIO | CHECK/REPLACE IC4001 | |
GE | VG4210 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 218966) | |
GE | VG4210 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4210 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (470uF @ 16v - P/N# 176251) | |
GE | VG4215 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4215 | N/A | DEAD - NO CLOCK OR CLOCK PULSATES ON/OFF - WILL NOT TAKE A TAPE | CHECK/REPLACE C09 IN POWER SUPPLY (22uF @ 16v) | |
GE | VG4215 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (470uF @ 16v - P/N# 176251) | |
GE | VG4215 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 218966) | |
GE | VG4216 | N/A | DEAD - NO POWER | CHECK/REPLACE D1103 AND D1104 | |
GE | VG4216 | N/A | TAPE WON'T LOAD | CHECK/REPLACE D111 AND D112 | |
GE | VG4216 | N/A | LOUD GRINDING NOISE IN FAST FORWARD OR REWIND | CHECK/REPLACE DRIVE CLUTCH WHEEL (210841) | |
GE | VG4216 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG4216 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG4216 | N/A | WILL NOT TUNE SOME CHANNELS CORRECTLY ON A HRC CABLE SYSTEM | CHANGE R409 TO A 100k AND ADD A 100k FROM PIN 14 OF IC401 TO GROUND | |
GE | VG4216 | N/A | NO DISPLAY | CHECK/REPLACE D105 AND D106 | |
GE | VG4216 | N/A | NO 'AL' 6 VOLTS | CHECK/REPLACE D1103 AND D1104 (MAY CHECK NORMAL) | |
GE | VG4216 | N/A | DEAD - NO POWER | CHECK/REPLACE D1103 AND D1104 | |
GE | VG4216 | N/A | VCR IS SQUEALING WHILE PLAYING OR RECORDING - NOT PLAYING OR REWINDING TO END OF TAPE - UNIT MAY STOP INTERMITTENTLY | CHECK/REPLACE TAKE-UP REEL (P/N# 207491) AND SUPPLY REEL (P/N# 207492) - BOTH PARTS HAVE BEEN REVISED | |
GE | VG4216 | N/A | CAPSTAN MOTOR WON'T RUN | CHECK/REPLACE D108,D109,D110 | |
GE | VG4216 | N/A | VCR WON'T ACCEPT SOME TAPES | CHECK/REPLACE ITEM H552 (P/N# 210845) WITH IMPROVED VERSION | |
GE | VG4216 | N/A | CASSETTE HANGS UP OR DOESN'T SIT PROPERLY WHEN TAPE IS LOADED | CHECK/REPLACE ITEM H552 (P/N# 210845), H573 (P/N# 207798), AND H556 (P/N# 201977) | |
GE | VG4216 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG4216 | N/A | NO 'AL' 6 VOLTS | CHECK/REPLACE D1103 AND D1104 (MAY CHECK NORMAL) | |
GE | VG4216 | N/A | CAPSTAN MOTOR WON'T RUN | CHECK/REPLACE D108,D109,D110 | |
GE | VG4216 | N/A | EATS TAPES WHEN GOING FROM PLAY TO EJECT | CHECK/REPLACE D108,D109,D110 FOR OPEN | |
GE | VG4216 | N/A | DEAD - NO CLOCK OR CLOCK PULSATES ON/OFF - WILL NOT TAKE A TAPE | CHECK/REPLACE C09 IN POWER SUPPLY (22uF @ 16v) | |
GE | VG4216 | N/A | LOUD GRINDING NOISE IN FAST FORWARD OR REWIND | CHECK/REPLACE DRIVE CLUTCH WHEEL (210841) | |
GE | VG4216 | N/A | WILL NOT ACCEPT TAPES | CHECK/REPLACE D112 AND D114 (IF PRESENT) | |
GE | VG4216 | N/A | NO BLUE BACKGROUND - CAN'T SET CLOCK OR PROGRAM - ALL OTHER VCR FUNCTIONS ARE NORMAL | CHECK/REPLACE IC901 | |
GE | VG4216 | N/A | NO DISPLAY | CHECK/REPLACE D105 AND D106 | |
GE | VG4216 | N/A | TAPE WON'T LOAD | CHECK/REPLACE D111 AND D112 | |
GE | VG4216 | N/A | EATS TAPES WHEN GOING FROM PLAY TO EJECT | CHECK/REPLACE D108,D109,D110 FOR OPEN | |
GE | VG4216 | N/A | WILL NOT TUNE SOME CHANNELS CORRECTLY ON A HRC CABLE SYSTEM | CHANGE R409 TO A 100k AND ADD A 100k FROM PIN 14 OF IC401 TO GROUND | |
GE | VG4217 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (220uF @ 16v - P/N# 189978) | |
GE | VG4217 | N/A | VCR WILL NOT MUTE WHEN GOING INTO FAST SEARCH OR REWIND SEARCH | CHECK/REPLACE IC5201 (P/N# 213840) | |
GE | VG4217 | N/A | VCR WILL NOT MUTE WHEN GOING INTO FAST SEARCH OR REWIND SEARCH | CHECK/REPLACE IC5201 (P/N# 213840) | |
GE | VG4217 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 212502) | |
GE | VG4217 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4217 | N/A | WILL NOT RECORD IN LP OR SLP BUT SP IS NORMAL | CHECK/REPLACE IC301 | |
GE | VG4217 | N/A | DEAD - FRONT DISPLAY PULSATES ON AND OFF | CHECK/REPLACE C14 (220uF @ 16v - P/N# 189978) | |
GE | VG4217 | N/A | CASSETTE TAPE WILL NOT LOAD OR EJECT OR CARRIAGE IS OUT OF TIME | CHECK/REPLACE RIGHT SIDE PLATE (P/N# 221066) | |
GE | VG4218 | N/A | WILL NOT ACCEPT TAPE - 12 VOLTS ON LOADING IC MISSING | CHECK/REPLACE D001 (33 VOLT ZENER) | |
GE | VG4218 | N/A | ERRATIC FAST FORWARD OPERATION - UNIT MAY NOT PLAY,SEARCH FORWARD OR FFWD - DOES MOVE IN REVIEW/REWIND - EATS TAPES | CHECK/REPLACE Q512 FOR LEAKAGE (CAPSTAN SWITCH) | |
GE | VG4218 | N/A | ON TUNER, PICTURE JUMPS AND IS PARTIALLY 'BLUE SCREEN' | CHECK/REPLACE C026 | |
GE | VG4218 | N/A | CLOCK DISPLAY ON BUT NO OTHER FUNCTIONS WORK - WILL NOT LOAD/EJECT TAPE | CHECK/REPLACE Z611 (CIRCUIT PROTECTOR) | |
GE | VG4218 | N/A | NO CHROMA OR INTERMITTENT CHROMA ON PLAYBACK BUT RECORD CHROMA IS OK WHEN PLAYED ON ANOTHER VCR | CHECK/REPLACE C416 | |
GE | VG4218 | N/A | ERRATIC FAST FORWARD OPERATION - UNIT MAY NOT PLAY,SEARCH FORWARD OR FFWD - DOES MOVE IN REVIEW/REWIND - EATS TAPES | CHECK/REPLACE Q512 FOR LEAKAGE (CAPSTAN SWITCH) | |
GE | VG4218 | N/A | WILL NOT ACCEPT TAPE - 12 VOLTS ON LOADING IC MISSING | CHECK/REPLACE D001 (33 VOLT ZENER) | |
GE | VG4218 | N/A | NO VIDEO ON PLAYBACK OR RECORD - AUDIO NORMAL | CHECK/REPLACE Q645 | |
GE | VG4218 | N/A | NO VIDEO ON PLAYBACK OR RECORD - AUDIO NORMAL | CHECK/REPLACE Q645 | |
GE | VG4218 | N/A | NO AUDI ON SELF-RECORDED TAPES | CHECK/REPLACE Z901 | |
GE | VG4218 | N/A | NO VIDEO ON PLAYBACK OR RECORD - AUDIO NORMAL | CHECK/REPLACE Q645 | |
GE | VG4218 | N/A | WILL NOT ACCEPT TAPE - 12 VOLTS ON LOADING IC MISSING | CHECK/REPLACE D001 (33 VOLT ZENER) | |
GE | VG4218 | N/A | WILL NOT RECORD AUDIO - PLAYBACK AUDIO/VIDEO ARE FINE | CHECK/REPLACE Z901 CIRCUIT PROTECTOR | |
GE | VG4218 | N/A | DEAD - SOMETIMES PART OF DISPLAY WILL LIGHT AND SOMETIMES THE DRUM MOTOR WILL TRY TO START | CHECK/REPLACE Z611 LEAKY | |
GE | VG4218 | N/A | WILL NOT RECORD AUDIO BUT VIDEO IS OK | CHECK/REPLACE Z901 | |
GE | VG4218 | N/A | ERRATIC FAST FORWARD OPERATION - UNIT MAY NOT PLAY,SEARCH FORWARD OR FFWD - DOES MOVE IN REVIEW/REWIND - EATS TAPES | CHECK/REPLACE Q512 FOR LEAKAGE (CAPSTAN SWITCH) | |
GE | VG4219 | N/A | WILL NOT POWER OFF AFTER A XPR RECORDING SESSION - GOES TO STOP AND REMAINS POWERED ON | CHECK/REPLACE IC01 WITH NEW TYPE (P/N# 211943) | |
GE | VG4219 | N/A | MECHANISM JAMS WHEN LOADING TAPE AROUND CYLINDER | CHECK/REPLACE LEVER K128 (P/N# 212321) WITH NEW TYPE - ALSO CHECK CAM GEAR FOR DAMAGED TEETH | |
GE | VG4219 | N/A | INTERMITTENT RECORDING OF LINEAR AUDIO - OLD AUDIO NOT BEING ERASED | CHANGE C722 TO 0.01uF (P/N# 174423), SHORT EITHER R724 OR R725, CHANGE R722 TO A 18k (P/N# 174366) | |
GE | VG4219 | N/A | FULL OSD IS NOT DISPLAYED WHEN CASSETTE TAPE IS IN VCR | CHECK/REPLACE IC01 WITH NEW TYPE (P/N# 211943) | |
GE | VG4230 | N/A | UNSTABLE OR WAVING PICTURE WHEN USING THE VCR'S RF CONVERTER | CHANGE R7005 TO A 200 1/4w. RESISTOR | |
GE | VG4230 | N/A | TAPE SLACK OCCURS WHEN GOING FROM F/F OR REW TO STOP MODE | CHECK/REPLACE 'T' BRAKE SPRING (P/N# 228959) | |
GE | VG4232 | N/A | TAPE SLACK OCCURS WHEN GOING FROM F/F OR REW TO STOP MODE | CHECK/REPLACE 'T' BRAKE SPRING (P/N# 228959) | |
GE | VG4232 | N/A | UNSTABLE OR WAVING PICTURE WHEN USING THE VCR'S RF CONVERTER | CHANGE R7005 TO A 200 1/4w. RESISTOR | |
GE | VG4233 | N/A | TAPE SLACK OCCURS WHEN GOING FROM F/F OR REW TO STOP MODE | CHECK/REPLACE 'T' BRAKE SPRING (P/N# 228959) | |
GE | VG4233 | N/A | UNSTABLE OR WAVING PICTURE WHEN USING THE VCR'S RF CONVERTER | CHANGE R7005 TO A 200 1/4w. RESISTOR | |
GE | VG4235 | N/A | PLAYBACK SPEED INCORRECT OR DISPLAY INDICATES THE WRONG SPEED | IF CAPSTAN MOTOR HAS BEEN REPLACED, BE SURE IT IS THE CORRECT TYPE - SHOULD BE (P/N# 220990) | |
GE | VG4238 | N/A | NO COLOR IN LP SEARCH | THIS IS NOT A MALFUNCTION BUT A DESIGN CHARACTERISTIC | |
GE | VG4238 | N/A | FRONT PANEL TRACKING BUTTONS INOPERATIVE | THESE BUTTONS CANNOT BE HELD DOWN - THEY HAVE TO BE PRESSED AND RELEASED REPEATEDLY | |
GE | VG4239 | N/A | NO COLOR IN LP SEARCH | THIS IS NOT A MALFUNCTION BUT A DESIGN CHARACTERISTIC | |
GE | VG4239 | N/A | FLUORESCENT DISPLAY FLASHES INTERMITTENTLY ONLY WHEN THE UNIT IS IN THE OFF MODE - MAY GO FROM TIME DISPLAY TO --:-- | ADD INTERRUPT CBA (P/N# 233213) | |
GE | VG4239 | N/A | FRONT PANEL TRACKING BUTTONS INOPERATIVE | THESE BUTTONS CANNOT BE HELD DOWN - THEY HAVE TO BE PRESSED AND RELEASED REPEATEDLY | |
GE | VG4239 | N/A | FLUORESCENT DISPLAY FLASHES INTERMITTENTLY ONLY WHEN THE UNIT IS IN THE OFF MODE - MAY GO FROM TIME DISPLAY TO --:-- | CHECK/REPLACE IC501 (P/N# 229329) | |
GE | VG4255 | N/A | CASSETTE TAPE DOES NOT SLOW DOWN AT THE END OF HIGH SPEED REWIND | CHECK/REPLACE DIODE LOCATED ON THE EMITTER LEG OF Q202 | |
GE | VG4255 | N/A | VCR TURNS OFF AFTER POWERED ON OR UNIT HAS EXCESSIVE DRUM SPEED | CHECK/RESOLDER CONNECTIONS ON 6 PIN POWER CONNECTOR TO THE DRUM MOTOR -- THIS CONNECTOR IS SURFACE MOUNTED | |
GE | VG4255 | N/A | DISTORTED/GARBLED LINEAR AUDIO DURING SLP PLAYBACK ONLY | CHECK/REPLACE IC601 (P/N# 231932) WITH NEW TYPE | |
GE | VG4255 | N/A | MISSING MENU ITEMS SUCH AS VCR PLUS AND HI-FI AUDIO OPTIONS - CUSTOMER UNABLE TO USE VCR PLUS | REMOVE D718,D719,D720 - ADD D707 AND D709 (P/N# 198589) TO OP. CBA-D707 CATH TO CATH OF D708, D707 ANODE TO D709 ANODE | |
GE | VG4255 | N/A | WAVY PICTURE ON PLAYBACK OR SQUEAL FROM CAPSTAN MOTOR | CHECK/REPLACE FELT PAD UNDER THE CAPSTAN MOTOR (P/N 233964) | |
GE | VG7500 | N/A | WILL NOT ERASE PREVIOUSLY RECORDED AUDIO - LINES IN THE PICTURE | CHECK/REPLACE Q504 (2SD261 OR ECG123AP) | |
GE | VG7500 | N/A | WILL NOT LOAD TAPE AND MISSING 15 VOLTS FROM POWER SUPPLY | CHECK FOR COLD SOLDER JOINTS ON POWER SUPPLY BOARD NEAR THE HEAT DINK MOUNTED REGULATOR TRANSISTORS. | |
GE | VG7500 | N/A | INTERMITTENT RECORDING OF AUDIO | CHECK/RESOLDER CONNECTIONS ON CN501 | |
GE | VG7500 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG7500 | N/A | Q501 FAILS-EVEN AFTER BIAS OSC. KIT WAS INSTALLED | CHECK FOR BROKEN LEADS ON C501 AND Q501 | |
GE | VG7500 | N/A | RECORDING GOES TO SNOW - E-E DISTORTED | CHECK/RESOLDER CONNECTIONS ON Q105 | |
GE | VG7500 | N/A | GOES TO STOP AFTER 3 SECONDS WHENN RECORDING - PLAYBACK OK | CHECK/RESOLDER CONNECTIONS ON Q105 AND Q109 | |
GE | VG7500 | N/A | WILL NOT PLAY/FF/REW IF ERASE TAB IS IN PLACE | CHECK IC206 | |
GE | VG7500 | N/A | MACHINE RUNS TOO FAST IN PLAYBACK | CHECK/REPLACE IC601 | |
GE | VG7500 | N/A | LOW VOLUME ON TUNER BUT PLAYS A TAPE FINE | CHECK/REPLACE IC0401 (LOW OUTPUT ON FM DETECTOR) | |
GE | VG7500 | N/A | RECORD/PLAY WERE FINE IN SP-BUT IN LP/SLP THE CAPSTAN SPEED WOULD RUN FAST. | CHECK Q205 FOR LEAKAGE | |
GE | VG7500 | N/A | SNOWY PIX ON ALL CHANNELS | CHECK Q406 | |
GE | VG7500 | N/A | POOR AUDIO - WARBLE IN AUDIO - INTERMITTENT - MAY TAKE AN HOUR OR SO TO SHOW UP. | CHECK C215 OR SOLDER CONNECTIONS | |
GE | VG7500 | N/A | DEAD - NO CLOCK OR POWER - ALL SWITCHED VOLTAGES ARE MISSING BUT ALL-TIME VOLTAGES ARE PRESENT | CHECK/REPLACE C102 (2.2uF @ 50v) | |
GE | VG7500 | N/A | NO TUNER AUDIO | CHECK C418 FOR OPEN/SHORT | |
GE | VG7500 | N/A | SNOWY E-E MODE | CHECK/REPLACE Q54 IN RF DEMODULATOR | |
GE | VG7500 | N/A | TAPE RECORDED IN LP SWITCHES TO EP IN PLAYBACK MODE | CHECK IC203 | |
GE | VG7500 | N/A | NO LOCK IN SLP ON PLAYBACK ONLY | CHECK IC203 | |
GE | VG7500 | N/A | AFTER WARM UP, VCR GOES INTO FAST SEARCH | CHECK/REPLACE IC206 | |
GE | VG7500 | N/A | DEAD - NO CLOCK OR POWER - ALL SWITCHED VOLTAGES ARE MISSING BUT ALL-TIME VOLTAGES ARE PRESENT | CHECK/REPLACE C102 (2.2uF @ 50v) | |
GE | VG7500 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG7500 | N/A | BLANK RASTER IN THE PLAYBACK MODE-- E-E IS NORMAL | CHECK C306 FOR HIGH LEAKAGE | |
GE | VG7500 | N/A | DRUM MOTOR WON'T RUN | CHECK XT301 (3.58MHz CRYSTAL) | |
GE | VG7500 | N/A | EATS TAPE WHEN EJECTING | CHECK/REPLACE TAKE-UP REEL BRAKE | |
GE | VG7500 | N/A | TAKE UP REEL TURNS THEN STOPS IN FF OR REW, STOPS AND EJECTS TAPE | CHECK/REPLACE R251 (470k) | |
GE | VG7500 | N/A | WILL NOT PLAY - DRUM DOES NOT RUN OR MAY GO INTO FREE RUN | CHECK/RESOLDER CONNECTIONS ON Q105 AND Q106 | |
GE | VG7500 | N/A | COLOR MISSING IN PLAYBACK OR RECORD | CHECK C347 FOR OPEN | |
GE | VG7500 | N/A | LOW VOLUME ON TUNER BUT PLAYS A TAPE FINE | CHECK/REPLACE IC0401 (LOW OUTPUT ON FM DETECTOR) | |
GE | VG7500 | N/A | TAPE LOADS AND ALL MOTORS START THEN UNIT UNLOADS | CHECK L106 FOR HIGH RESISTANCE | |
GE | VG7500 | N/A | NO CLOCK DISPLAY BUT UNIT DOES POWER UP AND PLAY | CHECK/RESOLDER CONNECTIONS ON PINS 1 & 2 OF CN203 | |
GE | VG7500 | N/A | WON'T TUNE STATION--ALL STATIONS LOOK SCRAMBLED | CHECK C413 FOR OPEN | |
GE | VG7500 | N/A | POOR AUDIO - WARBLE IN AUDIO - INTERMITTENT - MAY TAKE AN HOUR OR SO TO SHOW UP. | CHECK C215 OR SOLDER CONNECTIONS | |
GE | VG7500 | N/A | SHUTS OFF ON RECORD INTERMITTENT-SOMETIMES VCR WILL KICK THE TAPE OUT. | CHECK/CLEAN THE ERASE PROTECT SWITCH | |
GE | VG7510 | N/A | WILL NOT SWITCH FROM TV/VCR--12VOLT REGULATED SUPPLY IS LOW | CHECK/REPLACE Q1201 AND Q1202 FOR SHORT OR LEAKY | |
GE | VG7510 | N/A | SCREEN GOES BLACK WHEN PROGRAM BUTTON ON REMOTE IS PUSHED TO SET CLOCK. | CHECK/REPLACE IC3003 | |
GE | VG7510 | N/A | WILL NOT REWIND - MECHANICAL PROBLEM - MAY BE INTERMITTENT | CHECK/REPLACE SUB LEVER ASSEMBLY (VMMS0042) | |
GE | VG7510 | N/A | ONLY REWINDS WHEN POWERED UP | CHECK FOR OPEN SOLENOID (PS00029) | |
GE | VG7510 | N/A | WILL NOT REWIND AND EATS TAPES ON PLAYBACK | EXAMINE THE GEAR DIRECTLY BELOW MAIN DRIVE PULLEY. THIS IS ITEM# 141 ON THE BREAK DOWN. | |
GE | VG7510 | N/A | BREAK LIFTER ARM WHEN UNLOADING | CHECK FOR BENT METAL TAPE FLAP OPENER (RIGHT FRONT | |
GE | VG7510 | N/A | GOOD BLACK AND WHITE PIX DURING PLAYBACK BUT NO COLOR | CHECK TO SEE IF COMB FILTER IS INSTALLED PROPERLY | |
GE | VG7510 | N/A | ONLY REWINDS WHEN POWERED UP | CHECK FOR OPEN SOLENOID (PS00029) | |
GE | VG7510 | N/A | INTERMITTENTLY GOES TO BLUE SCRN.--REW/FF SCAN PIX IS OK | CHECK FOR DEFECTIVE C2014 OR C2015 OR SOLDER CONNECTIONS ON EITHER. | |
GE | VG7510 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7510 | N/A | NO TUNER VIDEO IN VCR MODE - NO OSD - NO UNSWITCHED 5 VOLTS | CHECK/REPLACE L7001 FOR OPEN | |
GE | VG7510 | N/A | VCR TURNS ON BUT ALL FUNCTIONS INOPERATIVE--DEW LIGHT ON | CHECK FOR COLD SOLDER CONNECTIONS BETWEEN PINS 2&5 OF SYSTEM CTRL. uPROC. (IC6001) | |
GE | VG7510 | N/A | BREAKS LIFTER ARM WHEN UNLOADING TAPE--LOADS OK | CHECK FOR BENT TAPE FLAP OPENER (RIGHT FRONT CORNER | |
GE | VG7510 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7510 | N/A | BLOWS AC LINE FUSE IMMEDIATELY | CHECK F1001,D1001,C1004,Q1001,Q1002,D1015,D1005 | |
GE | VG7510 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7510 | N/A | BLOWS AC LINE FUSE IMMEDIATELY | CHECK F1001,D1001,C1004,Q1001,Q1002,D1015,D1005 | |
GE | VG7510 | N/A | DEW INDICATOR IS ON BUT VCR HAS NO DEW SENSOR | CHECK THE GROUND TO THE DEW INPUT (PIN 77) ON THE MICROPROCESSOR (IC6001) | |
GE | VG7510 | N/A | LOW VOLUME ON TUNER BUT PLAYS A TAPE FINE | CHECK/REPLACE IC0401 (LOW OUTPUT ON FM DETECTOR) | |
GE | VG7510 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7515 | N/A | NOISY VIDEO,NOISE BANDS OR STREAKS IN PLAYBACK VIDEO | REMOVE VIDEO HEAD AND INSTALL (2) LOCK WASHERS (210807) ON SCREWS LOCATED UNDER DRUM. | |
GE | VG7515 | N/A | NO VIDEO BUT OSD WORKS NORMALLY | CHECK C317 FOR LEAKAGE | |
GE | VG7515 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG7515 | N/A | NOISY VIDEO,NOISE BANDS OR STREAKS IN PLAYBACK VIDEO | REMOVE VIDEO HEAD AND INSTALL (2) LOCK WASHERS (210807) ON SCREWS LOCATED UNDER DRUM. | |
GE | VG7515 | N/A | SHUTS OFF ON RECORD INTERMITTENT-SOMETIMES VCR WILL KICK THE TAPE OUT. | CHECK/CLEAN THE ERASE PROTECT SWITCH | |
GE | VG7515 | N/A | NO VIDEO BUT OSD WORKS NORMALLY | CHECK C317 FOR LEAKAGE | |
GE | VG7515 | N/A | SHUTS OFF ON RECORD INTERMITTENT-SOMETIMES VCR WILL KICK THE TAPE OUT. | CHECK/CLEAN THE ERASE PROTECT SWITCH | |
GE | VG7515 | N/A | CAPSTAN HAS INTERMITTENT SPEED CONTROL | CHECK/RESOLDER CONNECTIONS ON PATH BETWEEN IC601 PIN 26 AND R611 | |
GE | VG7515 | N/A | FRONT PANEL LOCKS UP - LOSS OF REMOTE OPERATION - MAY BE INTERMITTENT. | CHECK IC0601-IF THE TYPE NUMBER IS NOT UPD75116CW-091 THEN REPLACE WITH 195143-CHECK ALSO IR RECVR.192280 | |
GE | VG7515 | N/A | AUDIO MISSING IN PLAYBACK--NOT ERASING OLD AUDIO | CHECK IC601 | |
GE | VG7515 | N/A | FRONT PANEL LOCKS UP - LOSS OF REMOTE OPERATION - MAY BE INTERMITTENT. | CHECK IC0601-IF THE TYPE NUMBER IS NOT UPD75116CW-091 THEN REPLACE WITH 195143-CHECK ALSO IR RECVR.192280 | |
GE | VG7515 | N/A | NOISY VIDEO,NOISE BANDS OR STREAKS IN PLAYBACK VIDEO | REMOVE VIDEO HEAD AND INSTALL (2) LOCK WASHERS (210807) ON SCREWS LOCATED UNDER DRUM. | |
GE | VG7515 | N/A | DEAD SET | CHECK IC701 AND R705 | |
GE | VG7515 | N/A | CAPSTAN HAS INTERMITTENT SPEED CONTROL | CHECK/RESOLDER CONNECTIONS ON PATH BETWEEN IC601 PIN 26 AND R611 | |
GE | VG7515 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG7515 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG7515 | N/A | AUDIO MISSING IN PLAYBACK--NOT ERASING OLD AUDIO | CHECK IC601 | |
GE | VG7515 | N/A | FRONT PANEL LOCKS UP - LOSS OF REMOTE OPERATION - MAY BE INTERMITTENT. | CHECK IC0601-IF THE TYPE NUMBER IS NOT UPD75116CW-091 THEN REPLACE WITH 195143-CHECK ALSO IR RECVR.192280 | |
GE | VG7515 | N/A | NO E-E,RECORD INOPER.,AUTO PROG. INOPER.--PLAYBACK IS OK | CHECK IC904 | |
GE | VG7515 | N/A | GARBLED AUDIO | CHECK Q0501,R0501,C0502,L0501 | |
GE | VG7515 | N/A | FUZZY PICTURE ON TAPE OR TUNER - NO RECORD AUDIO OR PB | CHECK/REPLACE IC501,Q501 AND L0501 | |
GE | VG7515 | N/A | GARBLED AUDIO | CHECK Q0501,R0501,C0502,L0501 | |
GE | VG7520 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7520 | N/A | WILL NOT RECORD VIDEO OR SOUND | CHECK/REPLACE Q4002 AND T4001 | |
GE | VG7520 | N/A | WILL NOT SWITCH FROM TV/VCR--12VOLT REGULATED SUPPLY IS LOW | CHECK/REPLACE Q1201 AND Q1202 FOR SHORT OR LEAKY | |
GE | VG7520 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7520 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7575 | N/A | NOISY VIDEO,NOISE BANDS OR STREAKS IN PLAYBACK VIDEO | REMOVE VIDEO HEAD AND INSTALL (2) LOCK WASHERS (210807) ON SCREWS LOCATED UNDER DRUM. | |
GE | VG7575 | N/A | VCR INOPERATIVE-NO CLOCK-NO LED'S-CAPSTAN MOTOR RUNNING VERY SLOWLY-NO FUNCTIONS WORK | CHECK C107 FOR OPEN | |
GE | VG7575 | N/A | SHUTS OFF ON RECORD INTERMITTENT-SOMETIMES VCR WILL KICK THE TAPE OUT. | CHECK/CLEAN THE ERASE PROTECT SWITCH | |
GE | VG7575 | N/A | PLAYS BACK A PRE-RECORDED TAPE FINE BUT PLAYBACK OF A RECORDING IS ALL SNOW | CHECK/REPLACE L0301 FOR SHORT | |
GE | VG7575 | N/A | COLOR IS MISSING-ALL OTHER FUNCTIONS OK | CHECK C0345 FOR LEAKAGE | |
GE | VG7575 | N/A | FRONT PANEL LOCKS UP - LOSS OF REMOTE OPERATION - MAY BE INTERMITTENT. | CHECK IC0601-IF THE TYPE NUMBER IS NOT UPD75116CW-091 THEN REPLACE WITH 195143-CHECK ALSO IR RECVR.192280 | |
GE | VG7575 | N/A | NOISY VIDEO,NOISE BANDS OR STREAKS IN PLAYBACK VIDEO | REMOVE VIDEO HEAD AND INSTALL (2) LOCK WASHERS (210807) ON SCREWS LOCATED UNDER DRUM. | |
GE | VG7575 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG7575 | N/A | INSERT TAPE,MACHINE LOADS TAPE AROUND HEADS BUT NO MOTORS ARE RUNNING,THEN UNLOADS LEAVING TAPE HANGING FROM TAPE. | CHECK/CLEAN MODE SELECT SWITCH | |
GE | VG7575 | N/A | NO VIDEO IN VCR E-E OR PLAYBACK | CHECK C0317 FOR SHORTS | |
GE | VG7575 | N/A | LOW VOLUME ON TUNER BUT PLAYS A TAPE FINE | CHECK/REPLACE IC0401 (LOW OUTPUT ON FM DETECTOR) | |
GE | VG7575 | N/A | FRONT PANEL LOCKS UP - LOSS OF REMOTE OPERATION - MAY BE INTERMITTENT. | CHECK IC0601-IF THE TYPE NUMBER IS NOT UPD75116CW-091 THEN REPLACE WITH 195143-CHECK ALSO IR RECVR.192280 | |
GE | VG7610 | N/A | ONLY REWINDS WHEN POWERED UP | CHECK FOR OPEN SOLENOID (PS00029) | |
GE | VG7610 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7610 | N/A | BREAK LIFTER ARM WHEN UNLOADING | CHECK FOR BENT METAL TAPE FLAP OPENER (RIGHT FRONT | |
GE | VG7610 | N/A | WILL NOT REWIND AND EATS TAPES ON PLAYBACK | EXAMINE THE GEAR DIRECTLY BELOW MAIN DRIVE PULLEY. THIS IS ITEM# 141 ON THE BREAK DOWN. | |
GE | VG7610 | N/A | SCREEN GOES BLACK WHEN PROGRAM BUTTON ON REMOTE IS PUSHED TO SET CLOCK. | CHECK/REPLACE IC3003 | |
GE | VG7610 | N/A | WILL NOT REWIND - MECHANICAL PROBLEM - MAY BE INTERMITTENT | CHECK/REPLACE SUB LEVER ASSEMBLY (VMMS0042) | |
GE | VG7610 | N/A | INTERMITTENTLY GOES TO BLUE SCRN.--REW/FF SCAN PIX IS OK | CHECK FOR DEFECTIVE C2014 OR C2015 OR SOLDER CONNECTIONS ON EITHER. | |
GE | VG7610 | N/A | DEW INDICATOR IS ON BUT VCR HAS NO DEW SENSOR | CHECK THE GROUND TO THE DEW INPUT (PIN 77) ON THE MICROPROCESSOR (IC6001) | |
GE | VG7610 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7610 | N/A | NO TUNER VIDEO IN VCR MODE - NO OSD - NO UNSWITCHED 5 VOLTS | CHECK/REPLACE L7001 FOR OPEN | |
GE | VG7610 | N/A | BLOWS AC LINE FUSE IMMEDIATELY | CHECK F1001,D1001,C1004,Q1001,Q1002,D1015,D1005 | |
GE | VG7610 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7610 | N/A | WILL NOT SWITCH FROM TV/VCR--12VOLT REGULATED SUPPLY IS LOW | CHECK/REPLACE Q1201 AND Q1202 FOR SHORT OR LEAKY | |
GE | VG7610 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7615 | N/A | NOISY VIDEO,NOISE BANDS OR STREAKS IN PLAYBACK VIDEO | REMOVE VIDEO HEAD AND INSTALL (2) LOCK WASHERS (210807) ON SCREWS LOCATED UNDER DRUM. | |
GE | VG7620 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7620 | N/A | INTERMITTENTLY WON'T EJECT OR COME ON IN PROGRAM MODE AND OCCASIONALLY WON'T SHUT OFF | CHECK/RESOLDER CONNECTIONS ON CABLE FROM BASKET TO MAIN PCB | |
GE | VG7620 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7620 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7675 | N/A | NOISY VIDEO,NOISE BANDS OR STREAKS IN PLAYBACK VIDEO | REMOVE VIDEO HEAD AND INSTALL (2) LOCK WASHERS (210807) ON SCREWS LOCATED UNDER DRUM. | |
GE | VG7685 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7685 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7685 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7720 | N/A | WILL EJECT TAPE AT THE END OF REWINDING AND ATTEMPT TO LOAD TAPE AGAIN, THEN POWER SHUTS OFF | CHECK/REPLACE MODE SELECT SWITCH | |
GE | VG7720 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7720 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7720 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7725 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7725 | N/A | WILL NOT POWER UP (TAPE STUCK) | CHECK/REPLACE C1013,C1014,C1015 AND C1016 | |
GE | VG7725 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7725 | N/A | DEAD - NO DISPLAY OR POWER | CHECK/REPLACE C1015,C1016, C1018 AND C1019 | |
GE | VG7725 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7775 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7775 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7775 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7785 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7785 | N/A | WILL NOT POWER UP (TAPE STUCK) | CHECK/REPLACE C1013,C1014,C1015 AND C1016 | |
GE | VG7785 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7785 | N/A | DEAD - POWER SUPPLY SQUEALS - VOLTAGES TOO HIGH | CHECK/REPLACE C1021 IN POWER SUPPLY OPEN | |
GE | VG7785 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7795 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7795 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7795 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7910 | N/A | BREAK LIFTER ARM WHEN UNLOADING | CHECK FOR BENT METAL TAPE FLAP OPENER (RIGHT FRONT | |
GE | VG7910 | N/A | ONLY REWINDS WHEN POWERED UP | CHECK FOR OPEN SOLENOID (PS00029) | |
GE | VG7910 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7910 | N/A | SCREEN GOES BLACK WHEN PROGRAM BUTTON ON REMOTE IS PUSHED TO SET CLOCK. | CHECK/REPLACE IC3003 | |
GE | VG7910 | N/A | WILL NOT REWIND - MECHANICAL PROBLEM - MAY BE INTERMITTENT | CHECK/REPLACE SUB LEVER ASSEMBLY (VMMS0042) | |
GE | VG7910 | N/A | BLOWS AC LINE FUSE IMMEDIATELY | CHECK F1001,D1001,C1004,Q1001,Q1002,D1015,D1005 | |
GE | VG7910 | N/A | NO TUNER VIDEO IN VCR MODE - NO OSD - NO UNSWITCHED 5 VOLTS | CHECK/REPLACE L7001 FOR OPEN | |
GE | VG7910 | N/A | DEW INDICATOR IS ON BUT VCR HAS NO DEW SENSOR | CHECK THE GROUND TO THE DEW INPUT (PIN 77) ON THE MICROPROCESSOR (IC6001) | |
GE | VG7910 | N/A | WILL NOT SWITCH FROM TV/VCR--12VOLT REGULATED SUPPLY IS LOW | CHECK/REPLACE Q1201 AND Q1202 FOR SHORT OR LEAKY | |
GE | VG7910 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7910 | N/A | WILL NOT REWIND AND EATS TAPES ON PLAYBACK | EXAMINE THE GEAR DIRECTLY BELOW MAIN DRIVE PULLEY. THIS IS ITEM# 141 ON THE BREAK DOWN. | |
GE | VG7910 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7910 | N/A | INTERMITTENTLY GOES TO BLUE SCRN.--REW/FF SCAN PIX IS OK | CHECK FOR DEFECTIVE C2014 OR C2015 OR SOLDER CONNECTIONS ON EITHER. | |
GE | VG7910 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7920 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7920 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7920 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7925 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7925 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7925 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7975 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7975 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7975 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7980 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7980 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7980 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GE | VG7985 | N/A | SOLENOID WON'T PULL IN AND SOLENOID ITSELF IS FINE | CHECK/REPLACE Q6005 FOR OPEN | |
GE | VG7985 | N/A | ERRATIC OPERATION-LOADS TAPE IN VCR THEN NOTHING-MAY BEGIN TO PLAY TAPE AND JUST STOP BUT STAYS LOADED | CHECK/REPLACE MODE SWITCH ON RIGHT SIDE OF CASSETTE HOUSING AND HARD WIRE 4 WIRE PLUG CONNECTION. | |
GE | VG7985 | G LOAD | SOLENOID FAILURE | CAUSED BY A NOISY MODE SELECT SWITCH - INSTALL KIT# 190130 WHICH INCLUDES INSTRUCTIONS. | |
GOLDSTAR | GHV1210M | N/A | NO CAPSTAN SERVO LOCK | CHECK/REPLACE IC501 OR CAPACITOR AROUND IC501 | |
GOLDSTAR | GHV1210M | N/A | COUNTER WILL NOT COUNT | MODIFY PER SERVICE BULLETIN FOR GHV-1240M (MANUAL) | |
GOLDSTAR | GHV1210M | N/A | LOW REEL TORQUE ONLY ON PLAY AND RECORD | TIE A 10K ACROSS R623 TO IMPROVE TORQUE | |
GOLDSTAR | GHV1210M | N/A | DEW INDICATOR STAYS ON AND DRUM RUNS CONSTANTLY | CHECK/REPLACE DEW SENSOR OR IC606 - SHORT DEW SENSOR LEADS TO SEE IF INDICATOR GOES OUT. IF NOT, REPLACE IC606 | |
GOLDSTAR | GHV1233M | N/A | TAPE CURLING AT THE BOTTOM | CHECK/REPLACE CLUTCH DUE TO TOO MUCH TORQUE | |
GOLDSTAR | GHV1233M | N/A | COUNTER WILL NOT COUNT | MODIFY PER SERVICE BULLETIN FOR GHV-1240M (MANUAL) | |
GOLDSTAR | GHV1233M | N/A | UNIT GOES TO STOP MODE AFTER A FEW SECONDS | CHECK/REPLACE REEL SENSOR (P/N# 657-010A) AND CHANGE R634 TO A 1K | |
GOLDSTAR | GHV1240 | N/A | WILL NOT POWER UP-ALSO GOES TO REWIND WHEN PLUGGED IN | CHECK/REPLACE IC501 AND IC504 | |
GOLDSTAR | GHV1240 | N/A | TRACKING PROBLEMS - PIX/SNOW/PIX/SNOW | CHECK FOR COLD SOLDER CONNECTIONS ON PLUG P2D03 AND IC203. | |
GOLDSTAR | GHV1240 | N/A | TRACKING WILL NOT ADJUST | CHECK/REPLACE IC201 | |
GOLDSTAR | GHV1240 | N/A | ERRATIC CAPSTAN OPERATION | CHECK/RESOLDER CONNECTIONS ON PLUG P2D01,P2D02 AND P2D03 | |
GOLDSTAR | GHV1240M | N/A | COUNTER WILL NOT COUNT | MODIFY PER SERVICE BULLETIN FOR GHV-1240M (MANUAL) | |
GOLDSTAR | GHV1241 | N/A | TRACKING PROBLEMS - PIX/SNOW/PIX/SNOW | CHECK FOR COLD SOLDER CONNECTIONS ON PLUG P2D03 AND IC203. | |
GOLDSTAR | GHV1241 | N/A | WILL NOT POWER UP-ALSO GOES TO REWIND WHEN PLUGGED IN | CHECK/REPLACE IC501 AND IC504 | |
GOLDSTAR | GHV1241 | N/A | ERRATIC CAPSTAN OPERATION | CHECK/RESOLDER CONNECTIONS ON PLUG P2D01,P2D02 AND P2D03 | |
GOLDSTAR | GHV1241 | N/A | TRACKING WILL NOT ADJUST | CHECK/REPLACE IC201 | |
GOLDSTAR | GHV1243 | N/A | TRACKING WILL NOT ADJUST | CHECK/REPLACE IC201 | |
GOLDSTAR | GHV1243 | N/A | TRACKING PROBLEMS - PIX/SNOW/PIX/SNOW | CHECK FOR COLD SOLDER CONNECTIONS ON PLUG P2D03 AND IC203. | |
GOLDSTAR | GHV1243 | N/A | ERRATIC CAPSTAN OPERATION | CHECK/RESOLDER CONNECTIONS ON PLUG P2D01,P2D02 AND P2D03 | |
GOLDSTAR | GHV1243 | N/A | WILL NOT POWER UP-ALSO GOES TO REWIND WHEN PLUGGED IN | CHECK/REPLACE IC501 AND IC504 | |
GOLDSTAR | GHV1245 | N/A | TRACKING PROBLEMS - PIX/SNOW/PIX/SNOW | CHECK FOR COLD SOLDER CONNECTIONS ON PLUG P2D03 AND IC203. | |
GOLDSTAR | GHV1245 | N/A | ERRATIC CAPSTAN OPERATION | CHECK/RESOLDER CONNECTIONS ON PLUG P2D01,P2D02 AND P2D03 | |
GOLDSTAR | GHV1245 | N/A | TRACKING WILL NOT ADJUST | CHECK/REPLACE IC201 | |
GOLDSTAR | GHV1245 | N/A | WILL NOT POWER UP-ALSO GOES TO REWIND WHEN PLUGGED IN | CHECK/REPLACE IC501 AND IC504 | |
GOLDSTAR | GHV1250 | N/A | NO AUDIO ON RECORD-BIAS OSC. WON'T START | INCREASE R426 TO A 39k--CHECK Q409 AND Q413 | |
GOLDSTAR | GHV1250 | N/A | WILL NOT POWER UP-ALSO GOES TO REWIND WHEN PLUGGED IN | CHECK/REPLACE IC501 AND IC504 | |
GOLDSTAR | GHV1250 | N/A | ERRATIC CAPSTAN OPERATION | CHECK/RESOLDER CONNECTIONS ON PLUG P2D01,P2D02 AND P2D03 | |
GOLDSTAR | GHV1260M | N/A | DRUM MOTOR RUNS TOO SLOW FOR A FEW SECONDS THEN VCR SHUTS OFF | CHECK/RESOLDER CONNECTIONS ON DRUM MOTOR CONNECTOR | |
GOLDSTAR | GHV1265 | N/A | WILL NOT POWER UP-ALSO GOES TO REWIND WHEN PLUGGED IN | CHECK/REPLACE IC501 AND IC504 | |
GOLDSTAR | GHV1280 | N/A | NO DRUM OR CAPSTAN OPERATION | CHECK D5A1 FOR OPEN | |
GOLDSTAR | GHV1280 | N/A | DEAD-BLOWING FUSES | CHECK D101,F101 | |
GOLDSTAR | GHV1280M | N/A | INTERMITTENT SNOWY PIX-LOOKS JUST LIKE A BAD HEAD OR DIRTY. | CHECK FOR COLD SOLDER JOINTS ON P3001 OF HEAD AMP | |
GOLDSTAR | GHV1280M | N/A | INTERMITTENT SNOWY PIX-LOOKS JUST LIKE A BAD HEAD OR DIRTY. | CHECK FOR COLD SOLDER JOINTS OR NO SOLDER ON THE INDIVIDUAL HEADS OF THE UPPER DRUM (MUST REMOVE DRUM) | |
GOLDSTAR | GHV1280M | N/A | EXCESSIVE WOW AND FLUTTER | CHANGE R234 TO A 180k AND R238 TO A 27k | |
GOLDSTAR | GHV1280Q | N/A | EXCESSIVE WOW AND FLUTTER | CHANGE R234 TO A 180k AND R238 TO A 27k | |
GOLDSTAR | GHV1280Q | N/A | FM DEVIATION ADJUSTMENTS ARE TOO SENSITIVE | CHANGE R309 TO A 2.7k | |
GOLDSTAR | GHV1285M | N/A | EXCESSIVE WOW AND FLUTTER | CHANGE R234 TO A 180k AND R238 TO A 27k | |
GOLDSTAR | GHV1285Q | N/A | FM DEVIATION ADJUSTMENTS ARE TOO SENSITIVE | CHANGE R309 TO A 2.7k | |
GOLDSTAR | GHV1285Q | N/A | EXCESSIVE WOW AND FLUTTER | CHANGE R234 TO A 180k AND R238 TO A 27k | |
GOLDSTAR | GHV1290 | N/A | WASHED OUT VIDEO-LOW LUMINANCE LEVEL | CHECK IC302 (GOLDSTAR 669-051A) | |
GOLDSTAR | GHV1290M | N/A | INTERMITTENT OPERATION OF IC502 | CHECK/REMOVE R517 FROM THE CIRCUIT | |
GOLDSTAR | GHV1290M | N/A | PICTURE FLICKERS IN THE EP MODE AND WEAK COLOR | CHANGE R329 TO A 560 ohm | |
GOLDSTAR | GHV1700M | N/A | ERRATIC TAPE COUNTER OPERATION | CHANGE R510 TO 18k | |
GOLDSTAR | GHV1700M | N/A | INTERMITTENT OPERATION OF IC502 | CHECK/REMOVE R517 FROM THE CIRCUIT | |
GOLDSTAR | GHV1705M | N/A | ERRATIC TAPE COUNTER OPERATION | CHANGE R510 TO 18k | |
GOLDSTAR | GHV1705M | N/A | INTERMITTENT OPERATION OF IC502 | CHECK/REMOVE R517 FROM THE CIRCUIT | |
GOLDSTAR | GHV1900 | N/A | MANY VERTICAL BARS ON THE SCREEN THAT FLASH ON AND OFF IF THE CLOCK HASN'T BEEN SET. | CHECK/REPLACE IC801 | |
GOLDSTAR | GHV1900M | N/A | ERRATIC TAPE COUNTER OPERATION | CHANGE R517 TO 27k | |
GOLDSTAR | GHV1900M | N/A | WON'T LOAD A TAPE | CHECK/REPLACE LOADING BRACKET ASSY. (P/N# 321-223A) AND IC502 | |
GOLDSTAR | GHV1905 | N/A | WILL NOT TAKE OR EJECT TAPE | CHECK/REPLACE IC502 (P/N# ECG1716 OR BA6209N) | |
GOLDSTAR | GHV1905M | N/A | PIX WON'T LOCK IN WHEN CHANGING CHANNELS | CHECK ALIGNMENT OF AFT CIRCUIT | |
GOLDSTAR | GHV1905M | N/A | ERRATIC TAPE COUNTER OPERATION | CHANGE R517 TO 27k | |
GOLDSTAR | GHV1905M | N/A | INTERMITTENT AUDIO IN PLAYBACK | CHECK FOR A OPEN CONNECTION BETWEEN THE INPUT OF IC401 AND THE AUDIO HEAD | |
GOLDSTAR | GHV1905M | N/A | REWINDS WHEN PLUGGED IN | CHECK RESET CIRCUIT | |
GOLDSTAR | GHV1910 | N/A | MANY VERTICAL BARS ON THE SCREEN THAT FLASH ON AND OFF IF THE CLOCK HASN'T BEEN SET. | CHECK/REPLACE IC801 | |
GOLDSTAR | GHV4500 | N/A | PART CHANGE FOR RELIABILITY | CHANGE C119 FROM A 22uF/16V TO A 22uF/50V | |
GOLDSTAR | GHV4500M | N/A | WOW AND FLUTTER GREATER THAN NORMAL | CHECK/REPLACE CAPSTAN MOTOR,IC501 ALSO DELETE D297 AND D298 | |
GOLDSTAR | GHV4500M | N/A | TUNER AUDIO DISTORTED | CHANGE R708 TO 390 ohm - R709 TO 820 ohm AND C709 TO 27pf | |
GOLDSTAR | GHV4500M | N/A | OSD GRAPHICS SLANT | CHANGE C801 TO 33pF - L802 TO 15uH COIL (P/N 0LR0152K530) AND DELETE C802 | |
GOLDSTAR | GHV4500M | N/A | ERRATIC TAPE COUNTER OPERATION | CHANGE R516 TO A 27k | |
GOLDSTAR | GHV4700M | N/A | AUDIO DISTORTION | CHANGE R708 TO 390 ohm - R709 TO 820 ohm - C709 TO 27pf | |
GOLDSTAR | GHV4700M | N/A | WON'T RECORD AUDIO OR ERASE OLD AUDIO | CHECK/REPLACE R427 FOR OPEN (47k) | |
GOLDSTAR | GHV4700M | N/A | OSD TITLES ARE TOO DIM | CHANGE R864 TO A 8.2k | |
GOLDSTAR | GHV4700M | N/A | PICTURE DISTORTION DURING TITLE MODE (THE AUDIO OSC. INTERFERES W/THE VIDEO SIGNAL DURING REC) | REMOVE C871 FROM CIRCUIT | |
GOLDSTAR | GHV51FM | N/A | 1 KHz TONE IN AUDIO ON PLAYBACK | CHECK/REPLACE R401 OR OPEN GROUND TO THE GROUND SIDE OF HEAD | |
GOLDSTAR | GHV51FM | N/A | WILL NOT ACCEPT TAPE | CHECK IC602 | |
GOLDSTAR | GHV51FM | N/A | NO SPEED CONTROL - RUNAWAY ON PLAY | CHECK/REPLACE C247 AND C248 | |
GOLDSTAR | GHV5220M | N/A | EXCESSIVE WOW AND FLUTTER | CHANGE R234 TO A 180k AND R238 TO A 27k | |
GOLDSTAR | GHV5220M | N/A | WILL NOT RECORD A CONTROL TRACK ON TAPE - PRE-RECORDED TAPES WOULD PLAYBACK FINE ON ALL SPEEDS | CHECK/REPLACE IC201 (P/N# 668-156A) | |
GOLDSTAR | GHV5300M | N/A | NO TUNER VIDEO - ONLY A BLUE SCREEN | CHANGE RS05 TO A 10k | |
GOLDSTAR | GHV5300M | N/A | EXCESSIVE WOW AND FLUTTER | CHANGE R234 TO A 180k AND R238 TO A 27k | |
GOLDSTAR | GHV55FM | N/A | 1 KHz TONE IN AUDIO ON PLAYBACK | CHECK/REPLACE R401 OR OPEN GROUND TO THE GROUND SIDE OF HEAD | |
GOLDSTAR | GHV55FM | N/A | NO SPEED CONTROL - RUNAWAY ON PLAY | CHECK/REPLACE C247 AND C248 | |
GOLDSTAR | GHV55FM | N/A | WILL NOT ACCEPT TAPE | CHECK IC602 | |
GOLDSTAR | GHV57FM | N/A | CLOCK RUNS TOO FAST | REMOVE D807 AND CHANGE C907 TO A 22uF @ 50V AND IF PROBLEM STILL PERSISTS,CHANGE C907 TO A 47uF @ 50V | |
GOLDSTAR | GHV8200M | N/A | NO DRUM OR CAPSTAN ROTATION | CHECK/REPLACE R215 FOR OPEN - ALSO Vcc & Vdd TO IC201 | |
GOLDSTAR | GHV8500 | N/A | WHEN USING THE CHANNEL UP/DOWN BUTTONS,SOMETIMES THE PIX IS DISTORTED OR SET SKIPS CHANNELS | DELETE R706 | |
GOLDSTAR | GHV8500M | N/A | HI-FI AUDIO DROPS OUT INTERMITTENTLY | REMOVE R414 |
LAMSON
Digital Electronics Address: 1324-1326 Jose Abad Santos Ave.,Manila, Philippines TEL:00632-2559675 TEL/FAX:00632-2568130 Cellular:0922-8867809 0922-8867810 E-mail:[email protected]
YAHOO MESSENGER ID : myrna_q_ng or saishu_ng (old) Lamson Importers & Exporters Trading <We will not be
using the old address and phone no. in the future. Please be
noted when calling us, sending letters, parcels or buying our products>
|